Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/8867
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Aydın, Hakan Berk | - |
dc.contributor.author | Cheema, Jamal Ahmed | - |
dc.contributor.author | Arnmanath, Gopal | - |
dc.contributor.author | Toklucu, Cihan | - |
dc.contributor.author | Yücel, Müge | - |
dc.contributor.author | Özenler, Sezer | - |
dc.contributor.author | Yıldız, Ümit Hakan | - |
dc.date.accessioned | 2020-07-18T08:34:04Z | - |
dc.date.available | 2020-07-18T08:34:04Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.issn | 1873-3573 | - |
dc.identifier.uri | https://doi.org/10.1016/j.talanta.2019.120581 | - |
dc.identifier.uri | https://hdl.handle.net/11147/8867 | - |
dc.description.abstract | Conjugated polyelectrolytes (CPEs) have been widely used as reporters in colorimetric assays targeting nucleic acids. CPEs provide naked eye detection possibility by their superior optical properties however, as concentration of target analytes decrease, trace amounts of nucleic acid typically yield colorimetric responses that are not readily perceivable by naked eye. Herein, we report a pixelated analysis approach for correlating colorimetric responses of CPE with nucleic acid concentrations down to 1 nM, in plasma samples, utilizing a smart phone with an algorithm that can perform analytical testing and data processing. The detection strategy employed relies on conformational transitions between single stranded nucleic acid-cationic CPE duplexes and double stranded nucleic acid-CPE triplexes that yield distinct colorimetric responses for enabling naked eye detection of nucleic acids. Cationic poly[N,N,N-triethyl-3-((4-methylthiophen-3-yl)oxy)propan-1-aminium bromide] is utilized as the CPE reporter deposited on a polyvinylidene fluoride (PVDF) membrane for nucleic acid assay. A smart phone application is developed to capture and digitize the colorimetric response of the individual pixels of the digital images of CPE on the PVDF membrane, followed by an analysis using the algorithm. The proposed pixelated approach enables precise quantification of nucleic acid assay concentrations, thereby eliminating the margin of error involved in conventional methodologies adopted for interpretation of colorimetric responses, for instance, RGB analysis. The obtained results illustrate that a ubiquitous smart phone could be utilized for point of care colorimetric nucleic acids assays in complex matrices without requiring sophisticated software or instrumentation. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Talanta | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Conjugated polyelectrolyte | en_US |
dc.subject | Paper-based sensor | en_US |
dc.subject | Pixelated analysis | en_US |
dc.subject | Nucleic acid assay | en_US |
dc.subject | Point-of-care | en_US |
dc.subject | Diagnostic tool | en_US |
dc.title | Pixelated colorimetric nucleic acid assay | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Aydın, Hakan Berk | - |
dc.institutionauthor | Özenler, Sezer | - |
dc.institutionauthor | Yıldız, Ümit Hakan | - |
dc.institutionauthor | Toklucu, Cihan | - |
dc.institutionauthor | Yücel, Müge | - |
dc.department | İzmir Institute of Technology. Chemistry | en_US |
dc.department | İzmir Institute of Technology. Bioengineering | en_US |
dc.department | İzmir Institute of Technology. Computer Engineering | - |
dc.identifier.volume | 209 | en_US |
dc.identifier.wos | WOS:000509632900094 | en_US |
dc.identifier.scopus | 2-s2.0-85076903010 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.talanta.2019.120581 | - |
dc.identifier.pmid | 31892020 | en_US |
dc.relation.doi | 10.1016/j.talanta.2019.120581 | en_US |
dc.coverage.doi | 10.1016/j.talanta.2019.120581 | en_US |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 01. Izmir Institute of Technology | - |
crisitem.author.dept | 04.01. Department of Chemistry | - |
Appears in Collections: | Bioengineering / Biyomühendislik Chemistry / Kimya Computer Engineering / Bilgisayar Mühendisliği PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
1-s2.0-S0039914019312147-main.pdf | 5.7 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
17
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
15
checked on Nov 9, 2024
Page view(s)
2,324
checked on Nov 18, 2024
Download(s)
108
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.