Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/1945
Title: Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS)
Authors: Erdem, Aslı
Eroğlu, Ahmet Emin
Keywords: Absorption
Duolite GT-73
Microcolumn
Antimony compounds
Publisher: Elsevier Ltd.
Source: Erdem, A.,and Eroğlu, A. E. (2005). Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). Talanta, 68(1), 86-92. doi:10.1016/j.talanta.2005.04.041
Abstract: A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l-1) and the certified value (13.79 ± 0.42 μg l-1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l-1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l-1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l-1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated.
URI: http://doi.org/10.1016/j.talanta.2005.04.041
http://hdl.handle.net/11147/1945
ISSN: 0039-9140
0039-9140
1873-3573
Appears in Collections:Chemistry / Kimya
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
1945.pdfMakale192.9 kBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

27
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

27
checked on Nov 9, 2024

Page view(s)

288
checked on Nov 18, 2024

Download(s)

362
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.