Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/1945
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Erdem, Aslı | - |
dc.contributor.author | Eroğlu, Ahmet Emin | - |
dc.date.accessioned | 2016-07-20T13:34:40Z | |
dc.date.available | 2016-07-20T13:34:40Z | |
dc.date.issued | 2005-11 | |
dc.identifier.citation | Erdem, A.,and Eroğlu, A. E. (2005). Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). Talanta, 68(1), 86-92. doi:10.1016/j.talanta.2005.04.041 | en_US |
dc.identifier.issn | 0039-9140 | |
dc.identifier.issn | 0039-9140 | - |
dc.identifier.issn | 1873-3573 | - |
dc.identifier.uri | http://doi.org/10.1016/j.talanta.2005.04.041 | |
dc.identifier.uri | http://hdl.handle.net/11147/1945 | |
dc.description.abstract | A selective matrix removal/separation/enrichment method, utilizing a microcolumn of a chelating resin with SH functional groups (Duolite GT-73), was proposed for the determination of Sb(III) in waters by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS). The resin was selective to Sb(III) at almost all pH and acidity values employed, whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with l-cysteine. Spike recoveries were tested at various concentration levels in different water types and were found to vary between 85 and 118%. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined (13.3 ± 1.1 μg l-1) and the certified value (13.79 ± 0.42 μg l-1). The method was applied to several bottled drinking water samples for antimony determination with and without preconcentration and none of the samples were found to contain antimony above the permissible level (5 μg l-1). The characteristic concentration (the concentration of the analyte corresponding to an absorbance of 0.0044) was 0.55 μg l-1 and the 3 s limit of detection (LOD) based on five times preconcentration was 0.06 μg l-1. The applicability of the microcolumn separation/preconcentration/matrix removal method for flow injection systems was also demonstrated. | en_US |
dc.description.sponsorship | İYTE: 2001 FENYL 14 | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd. | en_US |
dc.relation.ispartof | Talanta | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Absorption | en_US |
dc.subject | Duolite GT-73 | en_US |
dc.subject | Microcolumn | en_US |
dc.subject | Antimony compounds | en_US |
dc.title | Speciation and preconcentration of inorganic antimony in waters by Duolite GT-73 microcolumn and determination by segmented flow injection-hydride generation atomic absorption spectrometry (SFI-HGAAS) | en_US |
dc.type | Article | en_US |
dc.authorid | TR8641 | en_US |
dc.institutionauthor | Erdem, Aslı | - |
dc.institutionauthor | Eroğlu, Ahmet Emin | - |
dc.department | İzmir Institute of Technology. Chemistry | en_US |
dc.identifier.volume | 68 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 86 | en_US |
dc.identifier.endpage | 92 | en_US |
dc.identifier.wos | WOS:000232815600014 | en_US |
dc.identifier.scopus | 2-s2.0-27144497503 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.talanta.2005.04.041 | - |
dc.identifier.pmid | 18970289 | en_US |
dc.relation.doi | 10.1016/j.talanta.2005.04.041 | en_US |
dc.coverage.doi | 10.1016/j.talanta.2005.04.041 | en_US |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 04.01. Department of Chemistry | - |
Appears in Collections: | Chemistry / Kimya PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
27
checked on Nov 22, 2024
WEB OF SCIENCETM
Citations
27
checked on Nov 9, 2024
Page view(s)
288
checked on Nov 18, 2024
Download(s)
362
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.