Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/7820
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ayrı, İlknur | - |
dc.contributor.author | Genişoğlu, Mesut | - |
dc.contributor.author | Gaygısız, Handan | - |
dc.contributor.author | Sofuoğlu, Aysun | - |
dc.contributor.author | Sofuoğlu, Sait Cemil | - |
dc.date.accessioned | 2020-07-18T03:35:12Z | - |
dc.date.available | 2020-07-18T03:35:12Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 1309-1042 | - |
dc.identifier.uri | https://doi.org/10.1016/j.apr.2020.05.019 | - |
dc.identifier.uri | https://hdl.handle.net/11147/7820 | - |
dc.identifier.uri | https://search.trdizin.gov.tr/yayin/detay/409701 | - |
dc.description.abstract | Household cleaning products are sources of volatile organic compounds (VOCs). Bleach containing products are a special case because reactions occur between chloride and their organic content such as surfactants, perfumes, etc., generating VOCs. This study aimed to determine concentration of 13 VOCs in bleach-containing automatic toilet cleaners, to estimate their indoor air concentrations and associated exposure and health risk levels. Experiments with products purchased from supermarkets were conducted in 20-mL headspace vials by placing 1 g of sample with and without water. Solid-phase micro extraction with a DVB/CAR/PDMS fiber assembly was used for adsorption of VOCs from the headspace, and analyzed using a GC-MS. The median carbon tetrachloride and chloroform concentrations of the studied products ranged from 5.03 × 10?3 to 2.37 × 10?2 ?g/g and 2.53 × 10?2 to 2.37 ?g/g, respectively. The modeled 95th percentile indoor air concentrations in a 1.6 m3 bathroom with no ventilation were estimated to be 1 and 20 ?g/m3 for carbon tetrachloride and chloroform, respectively. The 95th percentile carcinogenic risk associated even with the use of the highest content product, 3.72 × 10?7 and 8.62 × 10?7 for carbon tetrachloride and chloroform respectively, were below the acceptable risk. In conclusion, automatic toilet-bowl cleaners were found to be sources of VOCs, but their emission potentials are not high to cause considerable indoor air concentrations over their suggested product lifetime. In turn, carcinogenic risks associated with inhalation exposure are below the de Minimis risk level of 10?6. © 2020 | en_US |
dc.language.iso | en | en_US |
dc.publisher | Turkish National Committee for Air Pollution Research (TUNCAP) | en_US |
dc.relation.ispartof | Atmospheric Pollution Research | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Automatic toilet-bowl cleaners | en_US |
dc.subject | Bleach | en_US |
dc.subject | Exposure-risk | en_US |
dc.subject | Indoor air | en_US |
dc.subject | Ventilation | en_US |
dc.subject | VOCs | en_US |
dc.title | Bleach-containing automatic toilet-bowl cleaners as sources of VOCs, associated indoor air concentrations and carcinogenic risk | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Ayrı, İlknur | - |
dc.institutionauthor | Genişoğlu, Mesut | - |
dc.institutionauthor | Gaygısız, Handan | - |
dc.institutionauthor | Sofuoğlu, Aysun | - |
dc.institutionauthor | Sofuoğlu, Sait Cemil | - |
dc.department | İzmir Institute of Technology. Environmental Engineering | en_US |
dc.department | İzmir Institute of Technology. Chemical Engineering | en_US |
dc.identifier.wos | WOS:000593929700001 | en_US |
dc.identifier.scopus | 2-s2.0-85085658755 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.apr.2020.05.019 | - |
dc.relation.doi | 10.1016/j.apr.2020.05.019 | en_US |
dc.coverage.doi | 10.1016/j.apr.2020.05.019 | en_US |
dc.identifier.trdizinid | 409701 | en_US |
dc.identifier.wosquality | Q2 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.07. Department of Environmental Engineering | - |
crisitem.author.dept | 03.02. Department of Chemical Engineering | - |
crisitem.author.dept | 03.07. Department of Environmental Engineering | - |
Appears in Collections: | Chemical Engineering / Kimya Mühendisliği Environmental Engineering / Çevre Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection TR Dizin İndeksli Yayınlar / TR Dizin Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
1-s2.0-S1309104220301264-main.pdf | 2.9 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
3
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
2
checked on Nov 9, 2024
Page view(s)
1,274
checked on Nov 18, 2024
Download(s)
884
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.