Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/6114
Full metadata record
DC FieldValueLanguage
dc.contributor.authorAras, Nadir-
dc.contributor.authorYalçın, Şerife-
dc.date.accessioned2017-08-15T10:55:57Z-
dc.date.available2017-08-15T10:55:57Z-
dc.date.issued2016-03-01-
dc.identifier.citationAras, N., and Yalçın, Ş. (2016). Development and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after drying. Talanta, 149, 53-61. doi:10.1016/j.talanta.2015.11.031en_US
dc.identifier.issn0039-9140-
dc.identifier.issn1873-3573-
dc.identifier.urihttp://doi.org/10.1016/j.talanta.2015.11.031-
dc.identifier.urihttp://hdl.handle.net/11147/6114-
dc.description.abstractThe present study reports a fast and accurate methodology for laser-induced breakdown spectroscopic, LIBS, analysis of aqueous samples for environmental monitoring purposes. This methodology has two important attributes: one is the use of a 300 nm oxide coated silicon wafer substrate (Si+SiO2) for the first time for manual injection of 0.5 microliter aqueous metal solutions, and two is the use of high energy laser pulses focused outside the minimum focus position of a plano convex lens at which relatively large laser beam spot covers the entire droplet area for plasma formation. Optimization of instrumental LIBS parameters like detector delay time, gate width and laser energy has been performed to maximize atomic emission signal of target analytes; Cu, Mn, Cd and Pb. Under the optimal conditions, calibration curves were constructed and enhancements in the LIBS emission signal were obtained compared to the results of similar studies given in the literature. The analytical capability of the LIBS technique in liquid analysis has been improved. Absolute detection limits of 1.3 pg Cu, 3.3 pg Mn, 79 pg Cd and 48 pg Pb in 0.5 microliter volume of droplets were obtained from single shot analysis of five sequential droplets. The applicability of the proposed methodology to real water samples was tested on the Certified Reference Material, Trace Metals in Drinking Water, CRM-TMDW and on ICP multi-element standard samples. The accuracy of the method was found at a level of minimum 92% with relative standard deviations of at most 20%. Results suggest that 300 nm oxide coated silicon wafer has an excellent potential to be used as a substrate for direct analysis of contaminants in water supplies by LIBS and further research, development and engineering will increase the performance and applicability of the methodology.en_US
dc.description.sponsorshipIzmir Institute of Technology (2014-IYTE-31)en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofTalantaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectLiquid droplet analysisen_US
dc.subjectOxidized silicon wafer substrateen_US
dc.subjectSpectroscopic analysisen_US
dc.subjectLaser induced breakdown spectroscopyen_US
dc.subjectSilicon oxidesen_US
dc.titleDevelopment and validation of a laser-induced breakdown spectroscopic method for ultra-trace determination of Cu, Mn, Cd and Pb metals in aqueous droplets after dryingen_US
dc.typeArticleen_US
dc.authoridTR57067en_US
dc.authoridTR114593en_US
dc.institutionauthorAras, Nadir-
dc.institutionauthorYalçın, Şerife-
dc.departmentİzmir Institute of Technology. Chemistryen_US
dc.identifier.volume149en_US
dc.identifier.startpage53en_US
dc.identifier.endpage61en_US
dc.identifier.wosWOS:000368866900007en_US
dc.identifier.scopus2-s2.0-84947968640en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.talanta.2015.11.031-
dc.identifier.pmid26717813en_US
dc.relation.doi10.1016/j.talanta.2015.11.031en_US
dc.coverage.doi10.1016/j.talanta.2015.11.031en_US
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeArticle-
crisitem.author.dept03.07. Department of Environmental Engineering-
crisitem.author.dept04.01. Department of Chemistry-
Appears in Collections:Chemistry / Kimya
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
6114.pdfMakale2.19 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

30
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

28
checked on Mar 23, 2024

Page view(s)

560
checked on Apr 15, 2024

Download(s)

276
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.