dc.identifier.citationUgranlı, T., Toprak, M., Gürsoy, G., Çimrin, A. H., and Sofuoğlu, S. C. (2015). Indoor environmental quality in chemistry and chemical engineering laboratories at Izmir Institute of Technology. Atmospheric Pollution Research, 6(1), 147-153. doi:10.5094/APR.2015.017en_US
dc.identifier.issn1309-1042
dc.identifier.urihttp://doi.org/10.5094/APR.2015.017
dc.identifier.urihttp://hdl.handle.net/11147/4609
dc.description.abstractIndoor air pollution in university research laboratories may be important to building occupants, especially for those who work in the laboratories. In this study, indoor air quality (IAQ) and indoor environmental comfort were investigated in research laboratories of two departments at a university. PM2.5, PM10, TVOC (total volatile organic compounds), and CO concentrations, and three comfort variables which are temperature, relative humidity, and CO2 were measured. PM2.5 concentration was determined gravimetrically by collecting particles on glass fiber filters, whereas the remaining pollutants and comfort variables were measured using a monitoring device. IAQ measurements showed that levels of all pollutants were under the limits in both of the departments except for TVOC in one laboratory which had a mean concentration of 182 ppb. The comfort variables were in the comfort ranges for laboratories in both of the departments except for temperature in one laboratory with a mean value of 30 °C. In conclusion, measures are needed for extensive uses of organic solvents because ventilation may not be sufficient to keep VOC concentrations within the limits, and to provide thermal comfort.en_US
dc.language.isoengen_US
dc.publisherTurkish National Committee for Air Pollution Researchen_US
dc.relation.isversionof10.5094/APR.2015.017en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectComforten_US
dc.subjectIndoor air qualityen_US
dc.subjectLaboratoryen_US
dc.subjectIzmir Institute of Technologyen_US
dc.titleIndoor environmental quality in chemistry and chemical engineering laboratories at Izmir Institute of Technologyen_US
dc.typearticleen_US
dc.contributor.authorIDTR116126en_US
dc.contributor.authorIDTR59409en_US
dc.contributor.iztechauthorUgranlı, Tuğba
dc.contributor.iztechauthorToprak, Melis
dc.contributor.iztechauthorGürsoy, Gül
dc.contributor.iztechauthorSofuoğlu, Sait Cemil
dc.relation.journalAtmospheric Pollution Researchen_US
dc.contributor.departmentİYTE, Mühendislik Fakültesi, Kimya Mühendisliği Bölümüen_US
dc.identifier.volume6en_US
dc.identifier.issue1en_US
dc.identifier.startpage147en_US
dc.identifier.endpage153en_US
dc.identifier.wosWOS:000351543300017
dc.identifier.scopusSCOPUS:2-s2.0-84945480569
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record