Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/4609
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ugranlı, Tuğba | - |
dc.contributor.author | Toprak, Melis | - |
dc.contributor.author | Gürsoy, Gül | - |
dc.contributor.author | Çimrin, Arif H. | - |
dc.contributor.author | Sofuoğlu, Sait Cemil | - |
dc.date.accessioned | 2016-05-05T13:25:20Z | |
dc.date.available | 2016-05-05T13:25:20Z | |
dc.date.issued | 2015-01 | |
dc.identifier.citation | Ugranlı, T., Toprak, M., Gürsoy, G., Çimrin, A. H., and Sofuoğlu, S. C. (2015). Indoor environmental quality in chemistry and chemical engineering laboratories at Izmir Institute of Technology. Atmospheric Pollution Research, 6(1), 147-153. doi:10.5094/APR.2015.017 | en_US |
dc.identifier.issn | 1309-1042 | |
dc.identifier.issn | 1309-1042 | - |
dc.identifier.uri | http://doi.org/10.5094/APR.2015.017 | |
dc.identifier.uri | http://hdl.handle.net/11147/4609 | |
dc.description.abstract | Indoor air pollution in university research laboratories may be important to building occupants, especially for those who work in the laboratories. In this study, indoor air quality (IAQ) and indoor environmental comfort were investigated in research laboratories of two departments at a university. PM2.5, PM10, TVOC (total volatile organic compounds), and CO concentrations, and three comfort variables which are temperature, relative humidity, and CO2 were measured. PM2.5 concentration was determined gravimetrically by collecting particles on glass fiber filters, whereas the remaining pollutants and comfort variables were measured using a monitoring device. IAQ measurements showed that levels of all pollutants were under the limits in both of the departments except for TVOC in one laboratory which had a mean concentration of 182 ppb. The comfort variables were in the comfort ranges for laboratories in both of the departments except for temperature in one laboratory with a mean value of 30 °C. In conclusion, measures are needed for extensive uses of organic solvents because ventilation may not be sufficient to keep VOC concentrations within the limits, and to provide thermal comfort. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Turkish National Committee for Air Pollution Research (TUNCAP) | en_US |
dc.relation.ispartof | Atmospheric Pollution Research | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Comfort | en_US |
dc.subject | Indoor air quality | en_US |
dc.subject | Laboratory | en_US |
dc.subject | Izmir Institute of Technology | en_US |
dc.title | Indoor environmental quality in chemistry and chemical engineering laboratories at Izmir Institute of Technology | en_US |
dc.type | Article | en_US |
dc.authorid | TR116126 | en_US |
dc.authorid | TR59409 | en_US |
dc.institutionauthor | Ugranlı, Tuğba | - |
dc.institutionauthor | Toprak, Melis | - |
dc.institutionauthor | Gürsoy, Gül | - |
dc.institutionauthor | Sofuoğlu, Sait Cemil | - |
dc.department | İzmir Institute of Technology. Environmental Engineering | en_US |
dc.department | İzmir Institute of Technology. Chemical Engineering | en_US |
dc.identifier.volume | 6 | en_US |
dc.identifier.issue | 1 | en_US |
dc.identifier.startpage | 147 | en_US |
dc.identifier.endpage | 153 | en_US |
dc.identifier.wos | WOS:000351543300017 | en_US |
dc.identifier.scopus | 2-s2.0-84945480569 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.5094/APR.2015.017 | - |
dc.relation.doi | 10.5094/APR.2015.017 | en_US |
dc.coverage.doi | 10.5094/APR.2015.017 | en_US |
dc.identifier.wosquality | Q2 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 01. Izmir Institute of Technology | - |
crisitem.author.dept | 03.07. Department of Environmental Engineering | - |
Appears in Collections: | Chemical Engineering / Kimya Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
23
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
19
checked on Nov 9, 2024
Page view(s)
264
checked on Nov 18, 2024
Download(s)
246
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.