Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/13306
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Soran, Atilla | - |
dc.contributor.author | Bengur, Fuat Barış | - |
dc.contributor.author | Rodriguez, Wendy | - |
dc.contributor.author | Chroneos, Maria Z. | - |
dc.contributor.author | Sezgin, Efe | - |
dc.date.accessioned | 2023-04-19T12:36:44Z | - |
dc.date.available | 2023-04-19T12:36:44Z | - |
dc.date.issued | 2023 | - |
dc.identifier.issn | 1539-6851 | - |
dc.identifier.issn | 1557-8585 | - |
dc.identifier.uri | https://doi.org/10.1089/lrb.2022.0066 | - |
dc.identifier.uri | https://hdl.handle.net/11147/13306 | - |
dc.description.abstract | Introduction: The reported incidences of breast cancer-related lymphedema (LE) affecting the arms vary greatly. Reason for this variability includes different diagnostic techniques used across studies. In the current study, we compared the accuracy of indocyanine green lymphography (ICG_L) and bioimpedance spectroscopy (BIS) in detecting LE before presentation of clinical signs.Methods and Results: Patients with no initial detectable signs of clinical LE of their arms after axillary lymph node dissection or removal of >5 lymph nodes on sentinel lymph node biopsy were included. Subclinical LE was defined as BIS values outside the normal range [(>= 7 units (or >10 units)] or a 7-unit (or 10 unit) change between two measurements. We tracked ICG_L and BIS measurements for 133 potentially affected arms (n = 123). ICG_L detected signs of lymphatic flow disruption in 63 arms (47%). Based on the BIS value of 7 units, 60 arms (45%) had values outside the normal range. When using ICG_L-identified LE cases as true positives, BIS had a 54% accuracy (area under the curve [AUC] = 0.54) in detecting LE. Accuracy was 61% for subclinical LE symptoms when compared with ICG_L (AUC = 0.62). Both BIS and subclinical LE symptoms had <0.70 AUC-receiver characteristic operator curve, suggesting that BIS and development of subclinical LE symptoms are not adequate for identifying patients with subclinical LE.Conclusion: ICG_L is a reliable diagnostic tool for detecting early signs of lymphatic flow disruption in subclinical LE. Utilizing ICG_L to diagnose subclinical LE followed by a personalized treatment plan may provide patients the best chance of preventing disease progression. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Mary Ann Liebert | en_US |
dc.relation.ispartof | Lymphatic Research and Biology | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Breast cancer | en_US |
dc.subject | Bioimpedance spectroscopy | en_US |
dc.subject | Indocyanine green lymphography | en_US |
dc.title | Early detection of breast cancer-related lymphedema: Accuracy of indocyanine green lymphography compared with bioimpedance spectroscopy and subclinical lymphedema symptoms | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Sezgin, Efe | - |
dc.department | İzmir Institute of Technology. Food Engineering | en_US |
dc.identifier.wos | WOS:000954529900001 | en_US |
dc.identifier.scopus | 2-s2.0-85163176507 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1089/lrb.2022.0066 | - |
dc.identifier.pmid | 36946918 | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q3 | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.08. Department of Food Engineering | - |
Appears in Collections: | Food Engineering / Gıda Mühendisliği PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
1
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
3
checked on Nov 9, 2024
Page view(s)
216
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.