Title: Indoor Environmental Quality in Naturally Ventilated Schools of a Dusty Region: Excess Health Risks and Effect of Heating and Desert Dust Transport
Authors: Şahin, Çağrı
Rastgeldi Doğan, Tuba
Yıldız, Melek
Sofuoğlu, Sait Cemil
Keywords: Dust transport
Excess risk
Indoor air quality
Particulate Matter (PM)
Publisher: Wiley
Abstract: Indoor air quality (IAQ) is impacted by polluted outdoor air in naturally ventilated schools, especially in places where both anthropogenic and natural sources of ambient air pollution exist. CO2, PM2.5, PM10, temperature, relative humidity (RH), and noise were measured in five naturally ventilated primary schools in City of Sanliurfa, in a dusty region of Turkey, Southeast Anatolia. Excess risk levels were estimated for particulate matter. Investigation was conducted through an educational year including two seasons in terms of anthropogenic effect, that is, heating/non-heating, and natural effect, that is, desert dust transport/non-dust transport. The median CO2 concentration was measured to be >1000 ppm in all seasons/schools. Temperature and RH fell out of the comfort zone in October-December, during which pollutant concentrations were considerably increased, specifically in November, that heating and dust transport periods coincide. The overall mean indoor PM10 and PM2.5 levels were 58 and 31.8 mu g/m(3), respectively. Risk assessment indicate that both short (incidence of asthma symptoms in asthmatic children) and long-term (prevalence of bronchitis) effects are considerable with 10.9 (2.4-19.6)% and 19.5 (2.2-38.8)%, respectively. The findings suggest that mechanical ventilation retrofitting with particle filtration is needed to mitigate potential negative health consequences on children.
URI: http://dx.doi.org/10.1111/ina.13068
https://hdl.handle.net/11147/12403
ISSN: 0905-6947
Appears in Collections:Environmental Engineering / Çevre Mühendisliği
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
Indoor Air-2022-Sahin.pdf
  Until 2025-07-01
Article1.89 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

9
checked on Dec 20, 2024

WEB OF SCIENCETM
Citations

8
checked on Dec 21, 2024

Page view(s)

610
checked on Dec 23, 2024

Download(s)

2
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.