Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/11838
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Demirtepe, Hale | - |
dc.contributor.author | Melymuk, Lisa | - |
dc.contributor.author | Codling, Garry | - |
dc.contributor.author | Murinova, Lubica Palkovicova | - |
dc.contributor.author | Richterova, Denisa | - |
dc.contributor.author | Rasplova, Vladimira | - |
dc.contributor.author | Trnovec, Tomas | - |
dc.date.accessioned | 2021-12-02T18:16:18Z | - |
dc.date.available | 2021-12-02T18:16:18Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 0048-9697 | - |
dc.identifier.issn | 1879-1026 | - |
dc.identifier.uri | https://doi.org/10.1016/j.scitotenv.2021.146667 | - |
dc.identifier.uri | https://hdl.handle.net/11147/11838 | - |
dc.description.abstract | Indoor dust is an important exposure route to anthropogenic chemicals used in consumer products. Plasticizers are common product additives and can easily leach out of the product and partition to dust. Investigations of plasticizers typically focus on a subset of phthalate esters (PEs), but there are many more PEs in use, and alternative plasticizers (APs) are seeing greater use after recognition of adverse health effects of PEs. In this study we use full scan high resolution mass spectrometry for targeted and suspect screening of PEs and APs in house dust and to assess the potential risk of human exposure. House dust samples from Eastern Slovakia were investigated and concentrations of Sigma 12PEs and Sigma(5)APs ranged 12-2765 mu g/g and 45-13,260 mu g/g, respectively. APs were at similar levels to PEs, indicating common usage of these compounds in products in homes. Evaluation of individual compound toxicity combined with human intake via dust ingestion suggested PEs are of lower priority compared to semivolatile organic compounds such as polychlorinated biphenyls due to their lower toxicity. However, cumulative risk assessment (CRA) is a more appropriate evaluation of risk, considering the presences of many PEs in dust and their similar toxic mode of action. CRA based on median toxicity reference values (TRVs) suggested acceptable risks for dust ingestion, however, the wide range of literature-derived TRVs is a large uncertainty, especially for the APs. Use of newer TRVs suggest risk from dust ingestion alone, i.e. not even considering diet, inhalation, and dermal contact. Additionally, screening of full-scan instrumental spectra identified a further 40 suspect PE compounds, suggesting the CRA based on the 12 target PEs underestimates the risk. (C) 2021 Elsevier B.V. All rights reserved. | en_US |
dc.description.sponsorship | This research was supported by Czech Science Foundation [GAR 1920479S] , RECETOX Research Infrastructure [LM2018121] , Slovak Ministry of Health [2012/47SZU11] , and Center of Excellence of Environmental Health, [ITMS No. 26240120033] , funded by ESIF. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Science of the Total Environment | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Alternative plasticizer | en_US |
dc.subject | Cumulative risk assessment | en_US |
dc.subject | Indoor dust | en_US |
dc.subject | Phthalate ester | en_US |
dc.subject | Suspect screening | en_US |
dc.title | Targeted and suspect screening of plasticizers in house dust to assess cumulative human exposure risk | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Demirtepe, Hale | - |
dc.department | İzmir Institute of Technology. Environmental Engineering | en_US |
dc.identifier.volume | 781 | en_US |
dc.identifier.wos | WOS:000655619500004 | en_US |
dc.identifier.scopus | 2-s2.0-85103657069 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.scitotenv.2021.146667 | - |
dc.identifier.pmid | 33812101 | en_US |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.07. Department of Environmental Engineering | - |
Appears in Collections: | Environmental Engineering / Çevre Mühendisliği PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
1-s2.0-S0048969721017356-main.pdf | 907.29 kB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
16
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
14
checked on Nov 9, 2024
Page view(s)
1,554
checked on Nov 18, 2024
Download(s)
68
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.