Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/10140
Full metadata record
DC FieldValueLanguage
dc.contributor.authorLeccese, Francesco-
dc.contributor.authorSalvadori, Giacomo-
dc.contributor.authorTambellini, Giuseppe-
dc.contributor.authorKazanasmaz, Zehra Tuğçe-
dc.date.accessioned2021-01-24T18:32:32Z-
dc.date.available2021-01-24T18:32:32Z-
dc.date.issued2020-
dc.identifier.issn2352-3409-
dc.identifier.urihttps://doi.org/10.1016/j.dib.2020.106065-
dc.identifier.urihttps://hdl.handle.net/11147/10140-
dc.descriptionPubMed: 32775576en_US
dc.description.abstractLighting Cultural Heritage is a complex task: light is necessary for the act of seeing, it can even enhance the visual experience [1,2], in addition proper lighting can significantly cut down energy consumptions [3], but on the same time it has detrimental effects on exhibits, especially daylight. In order to safeguard the exhibits from damages, national and international standards provide specific recommendations for exhibits' exposure, based on their photosensitivity category. These recommendations are the annual luminous exposure(LO) and the Maximum Illuminance Level (E-max), museums' curators have to verify that the display lighting conditions comply with the standards. Historical buildings are often converted into museums but, as their original purpose was different, the lighting conditions are often inadequate (e.g. too much uncontrolled daylight), therefore the lighting conditions' adequacy of the space should be assessed [4]. As the name suggest the annual luminous exposure requires an annual monitoring campaign, unfortunately it often happens that exhibits have been exposed incorrectly for prolonged periods, and therefore it is very important to evaluate the need of a fast intervention. In this casuistry a prolonged measurement campaign is not acceptable. Simulations can help running a great number of analysis while reducing the length and expenses of a measurements campaign, however their previsions must be validated. This paper provides the data acquired through measurements and simulations inside the Cetacean Gallery of the Monumental Charterhouse of Calci, near Pisa (Tuscany Region, Italy). The data comprehends horizontal and vertical illuminance measurements, recorded on December the 6th, and simulations run in Grasshopper with the plugins Honeybee+ and Ladybug. The data are related to the research article entitled "Application of climate-based daylight simulation to assess lighting conditions of space and artworks in historical buildings: the case study of Cetacean Gallery of the Monumental Charterhouse of Calci", published on the Journal of Cultural Heritage [5]. (C) 2020 The Author(s). Published by Elsevier Inc.en_US
dc.description.sponsorshipThis research was partially funded by the University of Pisa as part of the biennial project: (Technical committee for the predisposition of cognitive studies aimed to the restoration, the conservation and the enhancement of the Charterhouse of Calci and its Museums) (2017-2019), University of Pisa board resolution N 7/2017, concerning thermal, acoustic and lighting analysis. The project involves the University of Pisa (Technical Office for the Management and the Maintenance Activities on the building heritage, and School of Engineering), the Italian Ministry of Cultural Heritage and Activities, the Italian Heritage Protection Department.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofData in Briefen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDaylighting simulations accuracyen_US
dc.subjectAnnual measurement campaignen_US
dc.subjectClimate-based daylighting modelen_US
dc.subjectCultural heritage lightingen_US
dc.titleAssessing museums' daylighting adequacy without annual measurement campaign: Dataset of a confrontation between measured and simulated illuminance values inside the Cetacean Gallery of the Charterhouse of Calcien_US
dc.typeData Paperen_US
dc.institutionauthorKazanasmaz, Zehra Tuğçe-
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume32en_US
dc.identifier.wosWOS:000583229100030en_US
dc.identifier.scopus2-s2.0-85087817897en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.dib.2020.106065-
dc.identifier.pmid32775576en_US
dc.relation.doi10.1016/j.dib.2020.106065en_US
dc.coverage.doi10.1016/j.dib.2020.106065en_US
dc.identifier.scopusqualityQ1-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeData Paper-
crisitem.author.dept02.02. Department of Architecture-
Appears in Collections:Architecture / Mimarlık
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Veri Makaleleri / Data Papers
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
1-s2.0-S2352340920309598-main.pdf1.39 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

2
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

2
checked on Nov 9, 2024

Page view(s)

60,060
checked on Nov 18, 2024

Download(s)

318
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.