Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/7513
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kobya, Mehmet | - |
dc.contributor.author | Şık, Emrah | - |
dc.contributor.author | Demirbaş, Erhan | - |
dc.contributor.author | Gören, Ayşegül Yağmur | - |
dc.contributor.author | Öncel, Mehmet Salim | - |
dc.date.accessioned | 2019-12-23T12:07:46Z | |
dc.date.available | 2019-12-23T12:07:46Z | |
dc.date.issued | 2018 | en_US |
dc.identifier.citation | Kobya, M., Şık, E., Demirbaş, E., Gören, A. Y., and Öncel, M. S. (2018). Optimization of some cations for removal of arsenic from groundwater by electrocoagulation process. Environmental Engineering and Management Journal, 17(5), 1079-1093. | en_US |
dc.identifier.issn | 1582-9596 | - |
dc.identifier.issn | 1843-3707 | - |
dc.identifier.uri | https://hdl.handle.net/11147/7513 | |
dc.description.abstract | This study dealt with investigation of arsenic removal from groundwater using electrocoagulation (EC) method in a batch mode by the Box-Behnken experimental design method. Effects of some cations like Ca, Fe, Mg, Mn and operating time on the removal were explored by an air injected EC reactor. The combined effects of these variables were analyzed by the quadratic model for predicting the highest removal efficiency of arsenic from groundwater. The arsenic removal efficiency was found to be dependent on increase with operating time and concentrations of Ca, Mg, Fe and lower concentration of Mn. When operating variables were considered as minimum operating cost and maximum removal efficiency, the optimum operating parameters were determined to be 132 mg/L of CCa, 55 mg/L of CMg, 4.5 mg /L of CFe, 4.5 mg/L of CMn and operating time of 3 min to meet the target concentration of <10 μg/L. Values of removal efficiency and operating cost at the optimum conditions were 95.1% and 0.041 $/m3. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Gheorghe Asachi Technical University of Iasi | en_US |
dc.relation.ispartof | Environmental Engineering and Management Journal | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Arsenic removal | en_US |
dc.subject | Cations effects | en_US |
dc.subject | Electrocoagulation | en_US |
dc.subject | Groundwater | en_US |
dc.subject | Reactor design | en_US |
dc.title | Optimization of some cations for removal of arsenic from groundwater by electrocoagulation process | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Gören, Ayşegül Yağmur | - |
dc.department | İzmir Institute of Technology. Environmental Engineering | en_US |
dc.identifier.volume | 17 | en_US |
dc.identifier.issue | 5 | en_US |
dc.identifier.startpage | 1079 | en_US |
dc.identifier.endpage | 1093 | en_US |
dc.identifier.wos | WOS:000435676900007 | en_US |
dc.identifier.scopus | 2-s2.0-85050115643 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q3 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.07. Department of Environmental Engineering | - |
Appears in Collections: | Environmental Engineering / Çevre Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection Sürdürülebilir Yeşil Kampüs Koleksiyonu / Sustainable Green Campus Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
5
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
3
checked on Nov 9, 2024
Page view(s)
310
checked on Nov 18, 2024
Download(s)
90
checked on Nov 18, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.