Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/6676
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCoşkun, Turgay-
dc.contributor.authorGülhan, Özcan-
dc.contributor.authorŞahin, Cem Doğan-
dc.contributor.authorDurmuş Arsan, Zeynep-
dc.contributor.authorGökçen Akkurt, Gülden-
dc.date.accessioned2018-01-12T07:54:30Z-
dc.date.available2018-01-12T07:54:30Z-
dc.date.issued2017-
dc.identifier.citationCoşkun, T., Gülhan, Ö., Şahin, C. D., Durmuş Arsan, Z., and Gökçen Akkurt, G. (2017). The effect of spatial interventions on historic buildings' indoor climate (Case Study: Tire Necip Paşa Library, Izmir-Turkey). Energy Procedia, 133, 385-366. doi:10.1016/j.egypro.2017.09.362en_US
dc.identifier.issn1876-6102-
dc.identifier.issn1876-6102-
dc.identifier.urihttp://doi.org/10.1016/j.egypro.2017.09.362-
dc.identifier.urihttp://hdl.handle.net/11147/6676-
dc.description9th Mediterranean Conference of HVAC: Historical Buildings Retrofit in the Mediterranean Area, Climamed 2017; Matera; Italy; 12 May 2017 through 13 May 2017en_US
dc.description.abstractThe indoor climate of historic libraries should meet rigorous requirements related to human thermal comfort and conservation of books, manuscripts and cultural proper-ties. Paper based collections in historic libraries can be deteriorated chemically, mechanically and biologically because of inadequate indoor climate conditions. In this paper, Necip Paşa Library, the historic library located in Tire-Izmir, Turkey, was selected as a case study. The chemical, mechanical and biological degradation risks on the manuscripts were evaluated based on the indoor climate parameters measured for one year period. The Library, consisting of a main hall, a manuscript zone and an entrance hall, was modelled via the dynamic simulation software, Design Builder. Calibration of the model was conducted with respect to the measured indoor temperature and relative humidity values. The portico/Revak at the south facade of Library was converted into the entrance hall by wooden framed windows in 1930. To be able to see the effect of that intervention on the indoor climate (correspondingly on degradation risk of the manuscripts), a new model, namely semi-open model, was created and simulated. A remarkable change has not been observed on chemical degradation risk when the results of semi-open and existing library models were compared, while mechanical and biological degradation risks were less in semi-open model.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofEnergy Procediaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDynamic simulation modelen_US
dc.subjectHistoric libraryen_US
dc.subjectIndoor climateen_US
dc.subjectSpatial interventionen_US
dc.titleThe effect of spatial interventions on historic buildings' indoor climate (Case Study: Tire Necip Paşa Library, Izmir-Turkey)en_US
dc.typeConference Objecten_US
dc.authoridTR55992en_US
dc.authoridTR131301en_US
dc.authoridTR130569en_US
dc.institutionauthorCoşkun, Turgay-
dc.institutionauthorGülhan, Özcan-
dc.institutionauthorŞahin, Cem Doğan-
dc.institutionauthorDurmuş Arsan, Zeynep-
dc.institutionauthorGökçen Akkurt, Gülden-
dc.departmentİzmir Institute of Technology. Energy Systems Engineering-
dc.departmentİzmir Institute of Technology. Mechanical Engineering-
dc.departmentİzmir Institute of Technology. Energy Systems Engineeringen_US
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume133en_US
dc.identifier.startpage358en_US
dc.identifier.endpage366en_US
dc.identifier.wosWOS:000425679100031en_US
dc.identifier.scopus2-s2.0-85032580750en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.egypro.2017.09.362-
dc.relation.doi10.1016/j.egypro.2017.09.362en_US
dc.coverage.doi10.1016/j.egypro.2017.09.362en_US
local.message.claim2022-06-08T11:40:08.460+0300*
local.message.claim|rp00741*
local.message.claim|submit_approve*
local.message.claim|dc_contributor_author*
local.message.claim|None*
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityN/A-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeConference Object-
crisitem.author.dept03.10. Department of Mechanical Engineering-
crisitem.author.dept01. Izmir Institute of Technology-
crisitem.author.dept02.02. Department of Architecture-
crisitem.author.dept03.06. Department of Energy Systems Engineering-
Appears in Collections:Architecture / Mimarlık
Energy Systems Engineering / Enerji Sistemleri Mühendisliği
Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
6676.pdfMakale938.24 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

8
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

6
checked on Nov 9, 2024

Page view(s)

3,874
checked on Nov 18, 2024

Download(s)

170
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.