Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/6672
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBughrara, Khaled S. M.-
dc.contributor.authorDurmuş Arsan, Zeynep-
dc.contributor.authorGökçen Akkurt, Gülden-
dc.date.accessioned2018-01-11T12:06:54Z
dc.date.available2018-01-11T12:06:54Z
dc.date.issued2017
dc.identifier.citationBughrara, K. S. M., Durmuş Arsan, Z., and Gökçen Akkurt, G. (2017). Applying underfloor heating system for improvement of thermal comfort in historic mosques: The case study of Salepçioǧlu Mosque, Izmir, Turkey. Energy Procedia, 133, 290-299. doi:10.1016/j.egypro.2017.09.390en_US
dc.identifier.issn1876-6102
dc.identifier.issn1876-6102-
dc.identifier.urihttp://doi.org/10.1016/j.egypro.2017.09.390
dc.identifier.urihttp://hdl.handle.net/11147/6672
dc.description9th Mediterranean Conference of HVAC: Historical Buildings Retrofit in the Mediterranean Area, Climamed 2017; Matera; Italy; 12 May 2017 through 13 May 2017en_US
dc.description.abstractMosques differ from other types of buildings by having an intermittent operation schedule. Due to five prayer times per day throughout the year, mosques are fully or partially, yet periodically, occupied. This paper examines the potential of using an underfloor heating system for improvement of indoor thermal comfort in a historic mosque, which is naturally ventilated, heated and cooled, based on adaptive thermal comfort method. The selected Salepçioǧlu Mosque, housing valuable wall paintings, was built in 1905 in KemeraltI, Izmir, Turkey. It requires specific attention with its cultural heritage value. Firstly, indoor microclimate of the Mosque was monitored for one-year period of 2014-15. Then, dynamic simulation modelling tool, DesignBuilder v.4.2 was used to create the physical model of the Mosque. The ASHRAE Guideline 14 indices were utilized to calibrate the model, by comparing simulated and measured indoor air temperature to achieve hourly errors within defined ranges. The results of calibrated baseline model indicate that the Mosque does not satisfy acceptable thermal comfort levels for winter months that provided by the adaptive method. Then, the effect of underfloor heating was examined in the second model by the.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofEnergy Procediaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdaptive thermal comforten_US
dc.subjectHistoric mosqueen_US
dc.subjectRadiant heatingen_US
dc.subjectIndoor air temperatureen_US
dc.subjectSalepçioğlu Mosqueen_US
dc.titleApplying underfloor heating system for improvement of thermal comfort in historic mosques: The case study of Salepçioglu Mosque, Izmir, Turkeyen_US
dc.typeConference Objecten_US
dc.authoridTR131301en_US
dc.authoridTR130569en_US
dc.institutionauthorBughrara, Khaled S. M.-
dc.institutionauthorDurmuş Arsan, Zeynep-
dc.institutionauthorGökçen Akkurt, Gülden-
dc.departmentİzmir Institute of Technology. Energy Systems Engineering
dc.departmentİzmir Institute of Technology. Energy Systems Engineeringen_US
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume133en_US
dc.identifier.startpage290en_US
dc.identifier.endpage299en_US
dc.identifier.wosWOS:000425679100025en_US
dc.identifier.scopus2-s2.0-85032576365en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.egypro.2017.09.390-
dc.relation.doi10.1016/j.egypro.2017.09.390en_US
dc.coverage.doi10.1016/j.egypro.2017.09.390en_US
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityN/A-
dc.identifier.wosqualityttpTop10%en_US
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextopen-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairetypeConference Object-
item.languageiso639-1en-
crisitem.author.dept02.02. Department of Architecture-
crisitem.author.dept03.06. Department of Energy Systems Engineering-
Appears in Collections:Architecture / Mimarlık
Energy Systems Engineering / Enerji Sistemleri Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
6672.pdfConference Paper1.98 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

22
checked on Nov 22, 2024

WEB OF SCIENCETM
Citations

17
checked on Nov 9, 2024

Page view(s)

2,866
checked on Nov 18, 2024

Download(s)

214
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.