dc.contributor.authorŞahin, Cem Doğan-
dc.contributor.authorÇoşkun, Turgay-
dc.contributor.authorDurmuş Arsan, Zeynep-
dc.contributor.authorGökçen Akkurt, Gülden-
dc.date.accessioned2017-10-18T07:32:25Z-
dc.date.available2017-10-18T07:32:25Z-
dc.date.issued2017-04-
dc.identifier.citationŞahin, C. D., Çoşkun, T., Durmuş Arsan, Z., and Gökçen Akkurt, G. (2017). Investigation of indoor microclimate of historic libraries for preventive conservation of manuscripts. Case Study: Tire Necip Paşa Library, İzmir-Turkey. Sustainable Cities and Society, 30, 66-78. doi:10.1016/j.scs.2016.11.002en_US
dc.identifier.issn2210-6707-
dc.identifier.issn2210-6707-
dc.identifier.issn2210-6715-
dc.identifier.urihttp://doi.org/10.1016/j.scs.2016.11.002-
dc.identifier.urihttp://hdl.handle.net/11147/6377-
dc.description.abstractConservation of library collections requires an interdisciplinary approach. Dealing with the agents of deterioration via curative and preventive conservation methods has become a significant goal with new standards and norms in recent years. Preventive conservation aims indirect physical interventions such as climate control, good housekeeping and pest management. The aim of this study is to assess the degradation potential of indoor climate on valuable manuscripts that date back to 12th century, in a historic library in Tire-İzmir, Turkey. Through the study, first the library, namely Necip Paşa Library was continuously monitored by measurements of thermo-hygrometric parameters for one year. Then, the measured data were evaluated for the risk assessment based on the control classes of ASHRAE Chapter 21 to evaluate the mechanical, chemical and biological degradation risks. Finally, the conservation-oriented measures were proposed in order to keep the manuscripts under the better conditions. Results suggest that introducing a heating, ventilation and air-conditioning system to the building should be considered as the last option since natural hygrothermal behavior of the library gives reasonably sufficient evidences to prevent the manuscripts from degradations to some extent. Therefore, passive solutions should be given higher priorities not to disturb environmental past of the historic library.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofSustainable Cities and Societyen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectDegradation risksen_US
dc.subjectHistoric libraryen_US
dc.subjectIndoor climateen_US
dc.subjectManuscriptsen_US
dc.subjectPreventive conservationen_US
dc.subjectRisk assessmenten_US
dc.titleInvestigation of Indoor Microclimate of Historic Libraries for Preventive Conservation of Manuscripts. Case Study: Tire Necip Paşa Library, Izmir-Turkeyen_US
dc.typeArticleen_US
dc.authoridTR131301en_US
dc.authoridTR130569en_US
dc.institutionauthorŞahin, Cem Doğan-
dc.institutionauthorÇoşkun, Turgay-
dc.institutionauthorDurmuş Arsan, Zeynep-
dc.institutionauthorGökçen Akkurt, Gülden-
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.departmentİzmir Institute of Technology. Energy Systems Engineeringen_US
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume30en_US
dc.identifier.startpage66en_US
dc.identifier.endpage78en_US
dc.identifier.wosWOS:000398181700006en_US
dc.identifier.scopus2-s2.0-85011309701en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.scs.2016.11.002-
dc.relation.doi10.1016/j.scs.2016.11.002en_US
dc.coverage.doi10.1016/j.scs.2016.11.002en_US
local.message.claim2022-06-08T11:39:32.253+0300*
local.message.claim|rp00741*
local.message.claim|submit_approve*
local.message.claim|dc_contributor_author*
local.message.claim|None*
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.openairetypeArticle-
item.cerifentitytypePublications-
crisitem.author.dept01. Izmir Institute of Technology-
crisitem.author.dept03.10. Department of Mechanical Engineering-
crisitem.author.dept02.02. Department of Architecture-
crisitem.author.dept03.06. Department of Energy Systems Engineering-
Appears in Collections:Architecture / Mimarlık
Energy Systems Engineering / Enerji Sistemleri Mühendisliği
Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
6377.pdfMakale3.25 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

34
checked on Dec 20, 2024

WEB OF SCIENCETM
Citations

25
checked on Dec 21, 2024

Page view(s)

6,008
checked on Dec 16, 2024

Download(s)

788
checked on Dec 16, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.