Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/6371
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shukla, Sudheesh K. | - |
dc.contributor.author | Demir, Mustafa Muammer | - |
dc.contributor.author | Govender, Penny P. | - |
dc.contributor.author | Tiwari, Ashutosh | - |
dc.contributor.author | Shukla, S. K. | - |
dc.date.accessioned | 2017-10-17T11:09:44Z | |
dc.date.available | 2017-10-17T11:09:44Z | |
dc.date.issued | 2017-04 | - |
dc.identifier.citation | Shukla, S. K., Demir, M. M., Govender, P. P., Tiwari, A., and Shukla, S. K. (2017). Optical fibre based non-enzymatic glucose sensing over Cu2+-doped polyaniline hybrid matrix. Sensors and Actuators, B: Chemical, 242, 522-528. doi:10.1016/j.snb.2016.11.062 | en_US |
dc.identifier.issn | 0925-4005 | - |
dc.identifier.uri | http://doi.org/10.1016/j.snb.2016.11.062 | - |
dc.identifier.uri | http://hdl.handle.net/11147/6371 | - |
dc.description.abstract | The opto-chemical glucose sensing over cupric ion doped polyaniline (Cu+2/PANI) hybrid polymer matrix coated glass rod based optode has been demonstrated.Cu+2/PANI hybrid matrix was synthesized by in situ chemical polymerization of intrinsically functionalized aniline. Furthermore, developed optode has been explored for direct oxidisation of glucose on Cu+2/PANI hybrid matrix for non-enzymatic glucose sensing employing O-dianisidine indicator system. The proposed glucose sensor works well in range of 50 mg/dL–200 mg/dL with response time of 15 s in artificial as well as in biological samples along with 40 days of lifespan. © 2016 Elsevier B.V. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd. | en_US |
dc.relation.ispartof | Sensors and Actuators, B: Chemical | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Doping (additives) | en_US |
dc.subject | Optical biosensor | en_US |
dc.subject | Metal doped polymeric matrix | en_US |
dc.subject | In situ polymerisation | en_US |
dc.subject | Non-enzymatic glucose sensing | en_US |
dc.title | Optical Fibre Based Non-Enzymatic Glucose Sensing Over Cu2+-Doped Polyaniline Hybrid Matrix | en_US |
dc.type | Article | en_US |
dc.authorid | TR130614 | - |
dc.institutionauthor | Demir, Mustafa Muammer | - |
dc.department | İzmir Institute of Technology. Materials Science and Engineering | en_US |
dc.identifier.volume | 242 | en_US |
dc.identifier.startpage | 522 | en_US |
dc.identifier.endpage | 528 | en_US |
dc.identifier.wos | WOS:000393267700064 | - |
dc.identifier.scopus | 2-s2.0-84997040339 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.snb.2016.11.062 | - |
dc.relation.doi | 10.1016/j.snb.2016.11.062 | en_US |
dc.coverage.doi | 10.1016/j.snb.2016.11.062 | - |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.openairetype | Article | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
crisitem.author.dept | 03.09. Department of Materials Science and Engineering | - |
Appears in Collections: | Materials Science and Engineering / Malzeme Bilimi ve Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.