Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/5946
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Bayram, Göze | - |
dc.contributor.author | Kazanasmaz, Zehra Tuğçe | - |
dc.date.accessioned | 2017-07-18T08:49:55Z | |
dc.date.available | 2017-07-18T08:49:55Z | |
dc.date.issued | 2016 | |
dc.identifier.citation | Bayram, G., and Kazanasmaz, T. (2016). Simulation-based retrofitting of an educational building in terms of optimum shading device and energy efficient artificial lighting criteria. Light and Engineering, 24(2), 45-55. | en_US |
dc.identifier.issn | 0236-2945 | |
dc.identifier.issn | 0236-2945 | - |
dc.identifier.uri | http://hdl.handle.net/11147/5946 | |
dc.description.abstract | The high level of daylight performance is crucial to increase academic and work performance of students and staff in educational buildings which are mostly used during the daytime. New design solutions have potential to reach optimum lighting conditions and minimum energy consumption. So, the purpose of this study is to evaluate and propose an energy efficient lighting design for an educational building. The aim is to find the optimum type of shading device with appropriate slat angles, transmittance of glazing, and the luminaire type/layout as well. Utilizing DIALux simulations, scenarios for combinations of these inputs are tested for classrooms, offices and a laboratory, which are non-identical due to their orientation, size, window characterization and facade organization. The procedure covers all significant days (winter/ summer solstice and equinoxes) during one year. Such an integrated approach would be proposed for lighting design and retrofit applications. © 2016, LLC Editorial of Journal “Light Technik”. All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Znack Publishing House | en_US |
dc.relation.ispartof | Light and Engineering | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Energy efficiency | en_US |
dc.subject | Artificial lighting | en_US |
dc.subject | Daylighting | en_US |
dc.subject | Retrofitting | en_US |
dc.subject | Shading device | en_US |
dc.subject | School buildings | en_US |
dc.title | Simulation-based retrofitting of an educational building in terms of optimum shading device and energy efficient artificial lighting criteria | en_US |
dc.type | Article | en_US |
dc.authorid | TR28229 | en_US |
dc.institutionauthor | Bayram, Göze | - |
dc.institutionauthor | Kazanasmaz, Zehra Tuğçe | - |
dc.department | İzmir Institute of Technology. Architecture | en_US |
dc.identifier.volume | 24 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 45 | en_US |
dc.identifier.endpage | 55 | en_US |
dc.identifier.wos | WOS:000379374400006 | en_US |
dc.identifier.scopus | 2-s2.0-84976637591 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q4 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 02.02. Department of Architecture | - |
Appears in Collections: | Architecture / Mimarlık Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
7
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
5
checked on Nov 16, 2024
Page view(s)
410
checked on Nov 18, 2024
Download(s)
326
checked on Nov 18, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.