dc.contributor.author | Şahin, Cem Doğan | - |
dc.contributor.author | Durmuş Arsan, Zeynep | - |
dc.contributor.author | Tunçoku, Selim Sarp | - |
dc.contributor.author | Broström, Tor | - |
dc.contributor.author | Gökçen Akkurt, Gülden | - |
dc.date.accessioned | 2017-07-07T12:25:52Z | - |
dc.date.available | 2017-07-07T12:25:52Z | - |
dc.date.issued | 2015-06-01 | - |
dc.identifier.citation | Şahin, C.D., Durmuş Arsan, Z., Tunçoku, S.S., Broström, T., and Gökçen Akkurt, G. (2015). A transdisciplinary approach on the energy efficient retrofitting of a historic building in the Aegean Region of Turkey. Energy and Buildings, 96, 128-139. doi:10.1016/j.enbuild.2015.03.018 | en_US |
dc.identifier.issn | 0378-7788 | - |
dc.identifier.issn | 0378-7788 | - |
dc.identifier.uri | https://doi.org/10.1016/j.enbuild.2015.03.018 | - |
dc.identifier.uri | http://hdl.handle.net/11147/5891 | - |
dc.description.abstract | Abstract Buildings account for 40% of total energy consumption in the European Union, yet at the same time they have considerable energy saving potentials. Historic buildings should be treated different from contemporary ones when it comes to energy improvements. The specifications which underline historical, sociocultural and architectural values require certain care during realization of energy saving implementations to sustain these values. The purpose of this study is to demonstrate how the energy efficient retrofitting in historic buildings should be managed in a transdisciplinary approach with a case study conducted on the historic building in ̄zmir - Turkey. A detailed building energy simulation tool was used to determine the impacts of energy efficient retrofits. The actual energy consumption of case building was based on the utility bills regarding electricity and heating fuel consumption. Building energy simulation tool was calibrated by comparing the measured and simulated indoor air temperatures and total energy consumptions. The inappropriate retrofits, which contradict to the cultural heritage values, were eliminated with a transdisciplinary approach. Later appropriate retrofits were gathered into three packages to evaluate their effects on the energy consumption. The results show that energy saving of more than 34% can be obtained without damaging the heritage values. | en_US |
dc.description.sponsorship | Swedish Energy Agency within the national R&D program for energy efficiency in historic buildings | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier Ltd. | en_US |
dc.relation.ispartof | Energy and Buildings | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Building energy simulation | en_US |
dc.subject | Cultural heritage value | en_US |
dc.subject | Energy efficiency | en_US |
dc.subject | Historic buildings | en_US |
dc.subject | Retrofitting | en_US |
dc.title | A transdisciplinary approach on the energy efficient retrofitting of a historic building in the Aegean Region of Turkey | en_US |
dc.type | Article | en_US |
dc.authorid | TR131301 | en_US |
dc.authorid | TR130569 | en_US |
dc.institutionauthor | Şahin, Cem Doğan | - |
dc.institutionauthor | Durmuş Arsan, Zeynep | - |
dc.institutionauthor | Tunçoku, Selim Sarp | - |
dc.institutionauthor | Gökçen Akkurt, Gülden | - |
dc.department | İzmir Institute of Technology. Energy Systems Engineering | en_US |
dc.identifier.volume | 96 | en_US |
dc.identifier.startpage | 128 | en_US |
dc.identifier.endpage | 139 | en_US |
dc.identifier.wos | WOS:000357222300012 | en_US |
dc.identifier.scopus | 2-s2.0-84925853546 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1016/j.enbuild.2015.03.018 | - |
dc.relation.doi | 10.1016/j.enbuild.2015.03.018 | en_US |
dc.coverage.doi | 10.1016/j.enbuild.2015.03.018 | en_US |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 01. Izmir Institute of Technology | - |
crisitem.author.dept | 02.02. Department of Architecture | - |
crisitem.author.dept | 02.01. Department of Conservation and Restoration of Cultural Heritage | - |
crisitem.author.dept | 03.06. Department of Energy Systems Engineering | - |
Appears in Collections: | Architecture / Mimarlık Conservation and Restoration of Cultural Heritage / Kültür Varlıklarını Koruma ve Onarım Energy Systems Engineering / Enerji Sistemleri Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
71
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
60
checked on Oct 26, 2024
Page view(s)
432
checked on Nov 18, 2024
Download(s)
850
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.