dc.identifier.citationSofuoğlu, S.C. and Moschandreas, D.J. (2003). The link between symptoms of off ice building occupants and in-office air pollution: the Indoor Air Pollution Index. Indoor Air, 13 (4), 332-343.en_US
dc.identifier.urihttp://hdl.handle.net/11147/4383-
dc.description.abstractThe lack of an effective indoor air quality (IAQ) metric causes communication concerns among building tenants (the public),buildi ng managers (decision-makers),and IAQ investigators (engineers). The Indoor Air Pollution Index (IAPI) is developed for office buildings to bridge this communication discord. The index, simple and easily understood,employ s the range of pollutant concentrations and concentrations in the subject building to estimate a unitless single number,the IAPI,between 0 (lowest pollution level and best IAQ) and ten (highest pollution level and worst IAQ). The index provides a relative measure of indoor air pollution for office buildings and ranks office indoor air pollution relative to the index distribution of the US office building population. Furthermore,the index associates well with occupant symptoms,pe rcentage of occupants with persistent symptoms. A tree-structured method is utilized in conjunction with the arithmetic mean as the aggregation function. The hierarchical structure of the method renders not only one index value,but also several sub-index values that are critical in the study of an office air environment. The use of the IAPI for IAQ management is illustrated with an example. The decomposition of the index leads to the ranking of sampled pollutants by their relative contribution to the index and the identification of dominant pollutant(s). This information can be applied to design an effective strategy for reducing in-office air pollution.en_US
dc.language.isoenen_US
dc.publisherBlackwell Publishingen_US
dc.relation.ispartofIndoor Airen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIndoor air pollutionen_US
dc.subjectOffice buildingsen_US
dc.subjectOccupant symptomsen_US
dc.subjectIndex formulationen_US
dc.subjectEnvironmental managementen_US
dc.titleThe link between symptoms of off ice building occupants and in-office air pollution: the Indoor Air Pollution Indexen_US
dc.typeArticleen_US
dc.authoridTR59409en_US
dc.institutionauthorSofuoğlu, Sait Cemil-
dc.departmentİzmir Institute of Technology. Chemical Engineeringen_US
dc.identifier.volume13en_US
dc.identifier.issue4en_US
dc.identifier.startpage332en_US
dc.identifier.endpage343en_US
dc.identifier.wosWOS:000186797000003en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
item.openairetypeArticle-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.cerifentitytypePublications-
item.grantfulltextopen-
crisitem.author.dept03.07. Department of Environmental Engineering-
Appears in Collections:Chemical Engineering / Kimya Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
4383.pdfMakale502.36 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

WEB OF SCIENCETM
Citations

36
checked on Mar 27, 2024

Page view(s)

430
checked on Mar 25, 2024

Download(s)

472
checked on Mar 25, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.