Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/4086
Full metadata record
DC FieldValueLanguage
dc.contributor.authorEroğlu, Ahmet Emin-
dc.contributor.authorVolkan, Mürvet-
dc.contributor.authorEroğlu, Tijen-
dc.contributor.authorAtaman, O. Yavuz-
dc.contributor.authorMark, Harry B.-
dc.date.accessioned2014-07-25T03:25:27Z-
dc.date.available2014-07-25T03:25:27Z-
dc.date.issued1998-11en_US
dc.identifier.citationVolkan, M., Eroğlu, T., Eroğlu, Ahmet E., Ataman, O. Yavuz, & Mark, Harry B. (1998). A novel sorbent tube for ambient hydrogen sulfide determination. Talanta, 47(3), 585–593. doi: 10.1016/S0039-9140(98)00083-6en_US
dc.identifier.issn0039-9140en_US
dc.identifier.issn0039-9140-
dc.identifier.urihttp://hdl.handle.net/11147/4086-
dc.identifier.urihttp://doi.org/10.1016/S0039-9140(98)00083-6en_US
dc.description.abstractA novel tubular device has been developed for hydrogen sulfide determination in air. Several substrates such as commercial silica gel and alumina TLC plates, silica gel powder, alumina, CaSO4, CaCO3, BaSO4, MgO, chalk, α-cellulose and ethyl cellulose were tested as solid substrates. 30–70-mesh silica gel was finally employed in glass tubes of 4.0 mm internal diameter. Silica gel is treated with 0.5 M aqueous CdCl2 solution, dried, filled into the glass tube and sample gas is passed through the device using nitrogen as the carrier gas where 70% relative humidity is employed. The analyte reacts with the solid substrate to form a luminescent spot whose length in the tube is measured and correlated to concentration. The flow rate was 68 ml min−1. The analytical system is linear in the range of 0.2–1.3 ppm H2S for the specified conditions. The prepared devices are stable at least for 3 months prior to sampling; and after sampling, the luminescing spot is stable also at least for 3 months.en_US
dc.language.isoenen_US
dc.publisherElsevier Ltd.en_US
dc.relation.ispartofTalantaen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectHydrogen sulfideen_US
dc.subjectRoom temperature luminescenceen_US
dc.subjectAir pollution controlen_US
dc.titleA novel sorbent tube for ambient hydrogen sulfide determinationen_US
dc.typeArticleen_US
dc.authoridTR8641-
dc.authoridTR11074-
dc.authoridTR1599-
dc.institutionauthorEroğlu, Ahmet Emin-
dc.departmentİzmir Institute of Technology. Chemistryen_US
dc.identifier.wosWOS:000076727800008en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/S0039-9140(98)00083-6-
dc.relation.doi10.1016/S0039-9140(98)00083-6en_US
dc.coverage.doi10.1016/S0039-9140(98)00083-6en_US
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
crisitem.author.dept04.01. Department of Chemistry-
Appears in Collections:Chemistry / Kimya
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
A novel sorbent tube for ambient.pdfAccepted version436.51 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

16
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

9
checked on Nov 9, 2024

Page view(s)

370
checked on Nov 18, 2024

Download(s)

266
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.