Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3976
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorAktaş, Enginen
dc.contributor.authorBoylu, Mert-
dc.date.accessioned2014-07-22T13:52:51Z-
dc.date.available2014-07-22T13:52:51Z-
dc.date.issued2005en
dc.identifier.urihttp://hdl.handle.net/11147/3976-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Civil Engineering, Izmir, 2005en
dc.descriptionIncludes bibliographical referencesen
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxi, 103 leavesen
dc.description.abstractThe Aegean is one of the most seismically active regions of Turkey. The Eqarthquake disasters which occurred in Turkey recently, obligate the seismic rehabilitation of existing buildings and the new construction projects produced to require well-detailed seismic strengthing. On the other hand, before starting an expensive project such as seismic rehabilitation, a benefit/cost analysis is needed to determine whether the proposed project is economically feasible. In this study, a benefit/cost analysis model for the seismic rehabilitation of existing reinforced concrete buildings in Izmir is presented. To express the seismicity of Izmir City, between 1900-2003, the magnitude of Ms 4.9 earthquakes which occurred in Izmir and its vicinity are used as data. The Poisson Model is used to calculate the probability of occurrence. For the seismic risk of Izmir which includes damage to buildings and loss, various damage estimation methods are described. As a generalization of all of the existing reinforced concrete buildings in Izmir Region, two existing reinforced concrete buildings with total building area of 735 square meters and 716 square meters, respectively, which have different social functions, are chosen to estimate whether the seismic rehabilitations of the investigated buildings are economically justified. As a result of the analysis, benefit/cost ratios of both structures are found greater than one which means both rehabilitation projects are economically feasible.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBenefit-cost analysisen
dc.subject.lccTH1501 .B78 2005en
dc.subject.lcshReinforced concrete construction--Turkey--İzmiren
dc.subject.lcshBuildings--Earthquake effects--Turkeyen
dc.subject.lcshEarthquakes--İzmir (Turkey)en
dc.titleA benefit/cost analysis for the seismic rehabilitation on existing reinforced concrete buildings in Izmiren_US
dc.typeMaster Thesisen_US
dc.institutionauthorBoylu, Mert-
dc.departmentThesis (Master)--İzmir Institute of Technology, Civil Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000333.pdfMasterThesis6.61 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

244
checked on Nov 18, 2024

Download(s)

158
checked on Nov 18, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.