Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/3733
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Eroğlu, Ahmet Emin | en |
dc.contributor.author | Erdem, Aslı | - |
dc.date.accessioned | 2014-07-22T13:52:14Z | - |
dc.date.available | 2014-07-22T13:52:14Z | - |
dc.date.issued | 2003 | en |
dc.identifier.uri | http://hdl.handle.net/11147/3733 | - |
dc.description | Thesis (Master)--İzmir Institute of Technology, Chemistry, İzmir, 2003 | en |
dc.description | Includes bibliographical references (leaves: 69-75) | en |
dc.description | Text in English; Abstract: Turkish and English | en |
dc.description | ix, 75 leaves | en |
dc.description.abstract | A selective separation/preconcentration method utilizing microcolumn of a chelating resin with -SH functional groups (Duolite GT-73) was proposed for the determination of Sb(III) in waters by segmented flow injection HGAAS. The selectivity of the resin towards Sb(III) and Sb(V) was not dependent on the pH of the solution; Sb(III) was retained by the resin quantitatively in a broad pH and acidity range whereas Sb(V) was not retained at all and could be determined after a pre-reduction step with L-cysteine.Spike recoveries were tested at various concentration levels in different water types and were found to vary between 80-110 %. Accuracy of the proposed methodology was checked by analyzing a standard reference material and a good correlation was found between the determined and the certified values. The method was applied to several bottled drinking water samples for antimony determination. The samples were found to contain no antimony above the permissible level (5 ug/L). The applicability of the microcolumn separation/preconcentration method for flow injection systems was also demonstrated.A similar separation system was proposed for Mn determination in waters. A macroporous resin with no functional groups (Amberlite XAD-7HP) was employed for the speciation of Mn(II) and Mn(VII) and was found to retain Mn(VII) at pH values from 4.0 to 12.0. Mn(II) was retained at a pH of 12.0, possibly due to MnO2 precipitation rather than adsorption by the resin. | en |
dc.language.iso | en | en_US |
dc.publisher | Izmir Institute of Technology | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject.lcc | QD96.A8 E73 2003 | en |
dc.subject.lcsh | Atomic absorption spectroscopy | en |
dc.subject.lcsh | Inorganic compounds--Analysis | en |
dc.subject.lcsh | Speciation | en |
dc.title | Speciation and preconcentration of inorganic antimony and manganese in waters using microcolumn-flow injection system and determination by atomic absorption spectrometry | en_US |
dc.type | Master Thesis | en_US |
dc.institutionauthor | Erdem, Aslı | - |
dc.department | Thesis (Master)--İzmir Institute of Technology, Chemistry | en_US |
dc.relation.publicationcategory | Tez | en_US |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.openairetype | Master Thesis | - |
item.languageiso639-1 | en | - |
Appears in Collections: | Master Degree / Yüksek Lisans Tezleri |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
T000285.pdf | MasterThesis | 1.07 MB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
120
checked on Nov 25, 2024
Download(s)
80
checked on Nov 25, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.