Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3612
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorKazanasmaz, Zehra Tuğçeen
dc.contributor.authorFırat Örs, Pelin-
dc.date.accessioned2014-07-22T13:51:56Z-
dc.date.available2014-07-22T13:51:56Z-
dc.date.issued2013en
dc.identifier.urihttp://hdl.handle.net/11147/3612-
dc.descriptionThesis (Master)--İzmir Institute of Technology, Architecture, İzmir, 2013en
dc.descriptionIncludes bibliographical references (leaves: 140-145)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxvi, 188 leavesen
dc.descriptionFull text release delayed at author's request until 2016.07.24en
dc.description.abstractThe daylighting performance is an important asset that deeply affects the occupant's visual comfort. In study and work environments, it is crucial to maintain adequate and uniformly distributed daylight. Deficiencies in daylighting conditions of these environments may cause health problems, work performance loss and excessive energy consumption. The varying nature of daylight in daily and yearly basis is a strong challenge on that matter. Advanced daylighting systems have been developed to overcome this challenge. Improving the daylighting performance of existing buildings is another difficulty in daylighting design, since the aspects like orientation, window area and surrounding elements affect indoor illuminance levels and uniformity. Thus, daylighting design needs should be carefully considered at the initial design stages of the buildings. Regarding to these, four architectural design studios facing southwest, southeast, northwest and northeast were selected in Izmir Institute of Technology Faculty of Architecture. In these studios, daylighting measurements including illuminance at specific points were conducted in May and June 2012. The aim of this thesis is to improve the illuminance and uniformity in the selected studios. Simulation models were built in Ecotect; and the field measurements were then used to validate the Ecotect model. To reach the best daylighting performance, simulations were carried out by Desktop Radiance with applying advanced daylighting systems, namely laser cut panels, prismatic panels and light shelves. The simulation findings were analyzed and discussed. It is considered that retrofitting efforts after the construction would be inadequate regarding daylighting, unless complying with the standards during the design process.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectArchitectural designen
dc.subject.lcshDaylightingen
dc.titleModeling of advanced daylighting systems to imporove illuminance and uniformity in architectural design studiosen_US
dc.typeMaster Thesisen_US
dc.authorid0000-0001-6547-8484-
dc.institutionauthorFırat Örs, Pelin-
dc.departmentThesis (Master)--İzmir Institute of Technology, Architectureen_US
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
10009710.pdfMasterThesis12.88 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

202
checked on Nov 18, 2024

Download(s)

116
checked on Nov 18, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.