dc.descriptionThesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2011en
dc.descriptionIncludes bibliographical references (leaves: 109-115)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxiv, 126 leavesen
dc.description.abstractAdsorption heat pumps are promising systems due to their ability to recover heat at low temperature levels and to provide cooling and/or heating effects. It has advantages such as using renewable energy sources, being environmental friendly, having no vibration and lower operation costs. In this study, the most common pairs used in adsorption heat pumps were reviewed and their thermophysical and adsorption behaviors were discussed. The adsorption equilibrium phenomena were explained in details. The different experimental methods for determination of adsorption equilibrium for pairs were explained and compared. The change of heat of adsorption according to the varying adsorbed amount was studied numerically for two different equilibrium equations. It is found that, the heat of adsorption for pairs fitting Dubinin-Astakhov equation has a decrease with increasing adsorbed amount, while the heat of adsorption for pairs fitting Freundlich equation does not depend on adsorbed amount. A numerical study was performed to investigate the performances and cooling capacities of three different adsorption chillers for six different pairs. The results showed that when S40 silica gels - water pair is used, the chiller cooled with low temperature source gives the highest performances.In the experimental section of the present study, a volumetric setup was designed and constructed. Experiments were performed for a conventional pair of silica gel - water. It was observed that the maximum adsorption capacity of the experimented silica gel -water pair was 21% (kg water vapor /kg silica gel) at 35 °C, 19% (kg water vapor/kg silica gel) at 45 °C and 11% (kg water vapor /kg silica gel) at 60 °C.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lcshHeat pumpsen
dc.subject.lcshAdsorptionen
dc.subject.lcshHeat of adsorptionen
dc.titleA study on isotherm characteristics of adsorbent-adsorbate pairs used in adsorption heat pumpsen_US
dc.typeMaster Thesisen_US
dc.institutionauthorYıldırım, Zeynep Elvan-
dc.departmentThesis (Master)--İzmir Institute of Technology, Energy Systems Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000969.pdfMasterThesis2.6 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

212
checked on Nov 18, 2024

Download(s)

126
checked on Nov 18, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.