Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/2497
Title: | Artificial neural networks to predict daylight illuminance in office buildings | Authors: | Kazanasmaz, Zehra Tuğçe Günaydın, Hüsnü Murat Binol, Selcen |
Keywords: | Artificial neural networks Building Daylighting Modeling Building parameters |
Publisher: | Elsevier Ltd. | Source: | Kazanasmaz, T., Günaydın, M., and Binol, S. (2009). Artificial neural networks to predict daylight illuminance in office buildings. Building and Environment, 44(8), 1751-1757. doi:10.1016/j.buildenv.2008.11.012 | Abstract: | A prediction model was developed to determine daylight illuminance for the office buildings by using artificial neural networks (ANNs). Illuminance data were collected for 3 months by applying a field measuring method. Utilizing weather data from the local weather station and building parameters from the architectural drawings, a three-layer ANN model of feed-forward type (with one output node) was constructed. Two variables for time (date, hour), 5 weather determinants (outdoor temperature, solar radiation, humidity, UV index and UV dose) and 6 building parameters (distance to windows, number of windows, orientation of rooms, floor identification, room dimensions and point identification) were considered as input variables. Illuminance was used as the output variable. In ANN modeling, the data were divided into two groups; the first 80 of these data sets were used for training and the remaining 20 for testing. Microsoft Excel Solver used simplex optimization method for the optimal weights. The model's performance was then measured by using the illuminance percentage error. As the prediction power of the model was almost 98%, predicted data had close matches with the measured data. The prediction results were successful within the sample measurements. The model was then subjected to sensitivity analysis to determine the relationship between the input and output variables. NeuroSolutions Software by NeuroDimensions Inc., was adopted for this application. Researchers and designers will benefit from this model in daylighting performance assessment of buildings by making predictions and comparisons and in the daylighting design process by determining illuminance. | URI: | http://dx.doi.org/10.1016/j.buildenv.2008.11.012 http://hdl.handle.net/11147/2497 |
ISSN: | 0360-1323 0360-1323 |
Appears in Collections: | Architecture / Mimarlık Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Show full item record
CORE Recommender
SCOPUSTM
Citations
112
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
83
checked on Oct 26, 2024
Page view(s)
644
checked on Nov 18, 2024
Download(s)
616
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.