Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/14366
Full metadata record
DC FieldValueLanguage
dc.contributor.authorChethan, K. N.-
dc.contributor.authorWaldschmidt, Nadine Schmidt Genannt-
dc.contributor.authorCorda, John Valerian-
dc.contributor.authorShenoy, Satish B.-
dc.contributor.authorShetty, Sawan-
dc.contributor.authorKeni, Laxmikant G.-
dc.contributor.authorMihcin, Senay-
dc.date.accessioned2024-05-05T14:57:04Z-
dc.date.available2024-05-05T14:57:04Z-
dc.date.issued2024-
dc.identifier.issn2057-1976-
dc.identifier.urihttps://doi.org/10.1088/2057-1976/ad2ff3-
dc.identifier.urihttps://hdl.handle.net/11147/14366-
dc.descriptionShenoy, Satish B/0000-0003-2374-3854; Valerian Corda, John/0000-0002-5677-9653; Mihcin, Senay/0000-0001-5077-8927; Keni, Dr Laxmikant/0000-0001-7010-7186; K N, Dr. Chethan/0000-0002-9399-685Xen_US
dc.description.abstractThe femur is one of the most important bone in the human body, as it supports the body's weight and helps with movement. The aging global population presents a significant challenge, leading to an increasing demand for artificial joints, particularly in knee and hip replacements, which are among the most prevalent surgical procedures worldwide. This study focuses on hip fractures, a common consequence of osteoporotic fractures in the elderly population. To accurately predict individual bone properties and assess fracture risk, patient-specific finite element models (FEM) were developed using CT data from healthy male individuals. The study employed ANSYS 2023 R2 software to estimate fracture loads under simulated single stance loading conditions, considering strain-based failure criteria. The FEM bone models underwent meticulous reconstruction, incorporating geometrical and mechanical properties crucial for fracture risk assessment. Results revealed an underestimation of the ultimate bearing capacity of bones, indicating potential fractures even during routine activities. The study explored variations in bone density, failure loads, and density/load ratios among different specimens, emphasizing the complexity of bone strength determination. Discussion of findings highlighted discrepancies between simulation results and previous studies, suggesting the need for optimization in modelling approaches. The strain-based yield criterion proved accurate in predicting fracture initiation but required adjustments for better load predictions. The study underscores the importance of refining density-elasticity relationships, investigating boundary conditions, and optimizing models through in vitro testing for enhanced clinical applicability in assessing hip fracture risk. In conclusion, this research contributes valuable insights into developing patient-specific FEM bone models for clinical hip fracture risk assessment, emphasizing the need for further refinement and optimization for accurate predictions and enhanced clinical utility.en_US
dc.language.isoenen_US
dc.publisherIop Publishing Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectfemur modellingen_US
dc.subjectdensityen_US
dc.subjectfractureen_US
dc.subjectstrainen_US
dc.subjectvon Mises stressen_US
dc.titlePatient-specific finite element analysis for assessing hip fracture risk in aging populationsen_US
dc.typeArticleen_US
dc.authoridShenoy, Satish B/0000-0003-2374-3854-
dc.authoridValerian Corda, John/0000-0002-5677-9653-
dc.authoridMihcin, Senay/0000-0001-5077-8927-
dc.authoridKeni, Dr Laxmikant/0000-0001-7010-7186-
dc.authoridK N, Dr. Chethan/0000-0002-9399-685X-
dc.departmentIzmir Institute of Technologyen_US
dc.identifier.volume10en_US
dc.identifier.issue3en_US
dc.identifier.wosWOS:001184079000001-
dc.identifier.scopus2-s2.0-85187550183-
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1088/2057-1976/ad2ff3-
dc.identifier.pmid38437729-
dc.authorscopusid57190621120-
dc.authorscopusid58934371800-
dc.authorscopusid57224615992-
dc.authorscopusid58880713200-
dc.authorscopusid57211660965-
dc.authorscopusid57200440479-
dc.authorscopusid58934442700-
dc.authorwosidShenoy, Satish B/B-2710-2015-
dc.authorwosidK N, Dr. Chethan/K-3415-2016-
dc.identifier.scopusqualityQ4-
item.fulltextNo Fulltext-
item.grantfulltextnone-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

128
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.