Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/13577
Full metadata record
DC FieldValueLanguage
dc.contributor.authorHalıcı, Ömer Faruk-
dc.contributor.authorDemir, Uğur-
dc.contributor.authorZabbar, Yassin-
dc.contributor.authorİlki, Alper-
dc.date.accessioned2023-07-27T19:49:53Z-
dc.date.available2023-07-27T19:49:53Z-
dc.date.issued2023-
dc.identifier.issn0141-0296-
dc.identifier.issn1873-7323-
dc.identifier.urihttps://doi.org/10.1016/j.engstruct.2023.116077-
dc.identifier.urihttps://hdl.handle.net/11147/13577-
dc.description.abstractThe infill walls made of Autoclaved Aerated Concrete (AAC), which is a lightweight, fire resistant and energy efficient material, provide effective insulation solutions for building types of structures and becoming more and more popular in earthquake prone regions. Although the number of experimental tests examining the seismic response of clay brick infills is extensive, the amount of prior research on infill walls built of AAC blocks is rather limited. Past research revealed that the use of bed-joint reinforcement is one of the promising solutions to improve the global seismic response of masonry walls by enhancing strength and displacement capacity. In this study, the out-of-plane (OOP) seismic performance of AAC infill walls with flat-truss and innovative cord-type bed-joint reinforcement is experimentally evaluated. Also, consideration is given to the prior in-plane (IP) damage, which was found to degrade the seismic performance of infills in OOP direction. For this purpose, three IP and four OOP, in total, seven experimental tests were performed on four full-scale AAC infill wall specimens. The test parameters were selected in such a way as to make it possible to parametrically compare the OOP performance of AAC infills with flat-truss and cord-type bed-joint reinforcements with unreinforced AAC infill walls, together with the effect of prior IP damage on the OOP response of unreinforced AAC infill walls. It was found that the use of innovative cord-type bed-joint reinforcement improved the OOP strength to a similar extent to what was obtained from the truss-type reinforced specimen. In terms of ultimate displacement and energy dissipation capacity enhancement, the specimen with cord-type reinforcement performed better. In addition, the damages formed due to IP cyclic displacement reversals up to 0.005 drift ratio, which is defined as the drift limit for buildings with brittle infill walls in certain design codes, resulted in a significant reduction in the OOP strength and stiffness properties of AAC infills. The theoretical OOP strength calculations were found to provide unconservative strength values for the IP-damaged specimens.en_US
dc.description.sponsorshipAll of the sources of funding for the work described in this publication are acknowledged below: 2211-a, scholarship reference number 1649B031700370. PhD scholarship granted to Omer Faruk Halicien_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofEngineering Structuresen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBed-joint reinforcementen_US
dc.subjectAutoclaved Aerated Concrete (AAC)en_US
dc.subjectInfill wallsen_US
dc.subjectExperimental seismic performance evaluationen_US
dc.subjectSliding Jointsen_US
dc.subjectMasonryen_US
dc.titleOut-of-plane seismic performance of bed-joint reinforced Autoclaved Aerated Concrete (AAC) infill walls damaged under cyclic in-plane displacement reversalsen_US
dc.typeArticleen_US
dc.authorid0000-0001-8319-2535-
dc.institutionauthorDemir, Uğurtr
dc.departmentİzmir Institute of Technology. Architectureen_US
dc.identifier.volume286en_US
dc.identifier.wosWOS:000992523800001en_US
dc.identifier.scopus2-s2.0-85162234295en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıtr
dc.identifier.doi10.1016/j.engstruct.2023.116077-
dc.authorscopusid57203428944-
dc.authorscopusid56490432600-
dc.authorscopusid58318475000-
dc.authorscopusid6603045524-
dc.identifier.wosqualityQ1-
dc.identifier.scopusqualityQ1-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.grantfulltextembargo_20250101-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.openairetypeArticle-
item.languageiso639-1en-
crisitem.author.dept02.02. Department of Architecture-
Appears in Collections:Architecture / Mimarlık
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
1-s2.0-S0141029623004911-main.pdf
  Until 2025-01-01
17.49 MBAdobe PDFView/Open    Request a copy
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Nov 22, 2024

WEB OF SCIENCETM
Citations

1
checked on Nov 9, 2024

Page view(s)

82
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.