Title: An investigation of the design process's effect on a high-performance building's actual energy system performance
Authors: Terim Çavka, Belgin
Çavka, Hasan Burak
Salehi, M. Mahdi
Keywords: Decision making
energy modeling
heat exchange
innovative technology
IDP
performance gap
high performance building
sustainability
Integrated Design
Net-Zero
Sustainability
Consumption
Publisher: Ios Press
Abstract: The design intent and the performance targets of projects may sometimes fail to match a building's actual post-occupancy performance. The mismatch of intended and actual building performance can be attributed to multifarious reasons. This study focuses on the role of project decisions made during design as one of the reasons of shortfall. The aim of the study is to unveil the design decision-making process of a state-of-the-art research building through the analysis of project's available set of IDP (Integrated Design Process) documentation. To understand the relationship and correlation between the energy performance gap and the decision-making process of the case building, we investigated the design decisions' effect on the actual performance. The particular emphasis is on the decisions that were based on assumptions rather than measured actual test data for the proposed innovative building systems. The designed heat recovery system, which was dependent on recovered heat from the neighboring research building, had a significant effect on the building's poor energy performance. We investigated collected project data from coordination meetings, thoroughly analyzed project documentation, and quantified the building's actual energy performance data. The analysis of the project information shows the ripple effect of decisions that were made based on assumptions, that triggered shortfalls in the building's overall actual performance. Our qualitative analysis indicates that the poor system performance during operations was related with the design decisions that were not based on the measurement of the actual performance of the existing systems in the neighboring building. The performance of the heat recovery from the neighboring building as a highly dependent Energy Conservation Measure (ECM) analyzed through collected documents and data. The ambiguity of the available heat potential from the neighboring building and related testing issues defined on an explanatory timeline of process coding. The conclusion includes recommendations for the design decision-making process for innovative system integrations for high-performance buildings, and underlines the importance of IDP for complex buildings.
URI: https://doi.org/10.3233/JID-220002
https://hdl.handle.net/11147/13318
ISSN: 1092-0617
1875-8959
Appears in Collections:Architecture / Mimarlık
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File SizeFormat 
13318.pdf1.79 MBAdobe PDFView/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

3
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

3
checked on Nov 9, 2024

Page view(s)

196
checked on Nov 18, 2024

Download(s)

70
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.