Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/12489
Title: Size-based microparticle seperation using negative magnetophoresis
Authors: Solmaz Özçelik, Özge
Öksüz, Cemre
Tekin, Hüseyin Cumhur
Keywords: Microfluidic filtration
Negative magnetophoresis
Size-based separation
Publisher: Chemical and Biological Microsystems Society
Abstract: We present a new size-based microparticle separation device using negative magnetophoresis. Microparticles spiked in the paramagnetic medium were filtered with respect to their sizes in a microfluidic channel placed between two magnets. Negative magnetophoresis allows large microparticles to be captured before the magnets, while small microparticles pass through the magnets under a constant flow. With this method, we reached 84.2% capturing efficiency of large microparticles (44 µm diameter) and capturing purity of 80.3% in the presence of small microparticles (17 µm diameter) at 3 µL/min flow rate. The capturing purity could further improve up to 99% by increasing the flow rate.
URI: https://hdl.handle.net/11147/12489
Appears in Collections:Bioengineering / Biyomühendislik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection

Show full item record



CORE Recommender

Page view(s)

240
checked on Nov 18, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.