Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/12142
Title: Simultaneous Validation of Wearable Motion Capture System for Lower Body Applications: Over Single Plane Range of Motion (rom) and Gait Activities
Authors: Mihçin, Şenay
Keywords: Range of motion
Gait analysis
Motion capture (MOCAP) systems
Proof of concept
Publisher: Walter de Gruyter GmbH
Abstract: Extracting data from {Zhu, 2019 #5} daily life activities is important in biomechanical applications to define exact boundary conditions for the intended use-based applications. Although optoelectronic camera-marker based systems are used as gold standard tools for medical applications, due to line-of-sight problem, there is a need for wearable, affordable motion capture (MOCAP) systems. We investigate the potential use of a wearable inertial measurement unit (IMU) based-wearable MOCAP system for biomechanical applications. The in vitro proof of concept is provided for the full lower body consisting of hip, knee, and ankle joints via controlled single-plane anatomical range of motion (ROM) simulations using an electrical motor, while collecting data simultaneously via opto-electronic markers and IMU sensors. On 15 healthy volunteers the flexion-extension, abduction-Adduction, internal-external rotation (ROM) values of hip and, the flexion-extension ROM values of the knee and ankle joints are calculated for both systems. The Bland-Altman graphs showed promising agreement both for in vitro and in vivo experiments. The maximum Root Mean Square Errors (RMSE) between the systems in vitro was 3.4° for hip and 5.9° for knee flexion motion in vivo, respectively. The gait data of the volunteers were assessed between the heel strike and toe off events to investigate the limits of agreement, calculating the population averages and standard deviation for both systems over the gait cycle. The maximum difference was for the ankle joint <6°. The results show that proposed system could be an option as an affordable-democratic solution.
URI: https://doi.org/10.1515/bmt-2021-0429
https://hdl.handle.net/11147/12142
ISSN: 0013-5585
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

SCOPUSTM   
Citations

12
checked on Dec 27, 2024

WEB OF SCIENCETM
Citations

11
checked on Dec 28, 2024

Page view(s)

5,042
checked on Dec 30, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.