Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/11818
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Mihçin, Şenay | - |
dc.contributor.author | Çıklaçandır, Samet | - |
dc.contributor.author | Koçak, Mertcan | - |
dc.contributor.author | Tosun, Aliye | - |
dc.date.accessioned | 2021-12-02T18:16:15Z | - |
dc.date.available | 2021-12-02T18:16:15Z | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 0148-0731 | - |
dc.identifier.issn | 1528-8951 | - |
dc.identifier.uri | https://doi.org/10.1115/1.4049199 | - |
dc.identifier.uri | https://hdl.handle.net/11147/11818 | - |
dc.description.abstract | Human motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions-abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg-were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11deg/0.30deg and 0.11deg/0.09deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland-Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected. | en_US |
dc.description.sponsorship | This research received a funding from Katip Celebi University (Scientific Research Project No. 2019-GAP-MUMF-0015). We would like to thank IKCU Mechatronics Department Faculty Members for allowing us to use their OptiTrack System and laboratory. We would like to thank Ph.D. student Mr. Serkan Cizmecioullar (Electric and Electronics Dept, Istanbul University, Turkey) for his support. We would like to acknowledge the support of Rokoko Team (Rokoko, Copenhagen, Denmark), with their technical support for this research. We also like to thank Professor Dr. James Shippen and Dr. Barbara May, in making the required changes for BoB (BoB, Coventry, UK) to be compatible with the Smartsuit Pro system. | en_US |
dc.language.iso | en | en_US |
dc.publisher | ASME | en_US |
dc.relation.ispartof | Journal of Biomechanical Engineering | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | MOCAP | en_US |
dc.subject | Motion analysis | en_US |
dc.subject | Human motion capture systems | en_US |
dc.subject | Lower body | en_US |
dc.subject | Wearable MOCAP | en_US |
dc.subject | Verification | en_US |
dc.subject | ISO13485 | en_US |
dc.title | Wearable Motion Capture System Evaluation for Biomechanical Studies for Hip Joints | en_US |
dc.type | Article | en_US |
dc.authorid | 0000-0001-5077-8927 | - |
dc.institutionauthor | Mihçin, Şenay | - |
dc.department | İzmir Institute of Technology. Mechanical Engineering | en_US |
dc.identifier.volume | 143 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.wos | WOS:000626080400016 | - |
dc.identifier.scopus | 2-s2.0-85107253680 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1115/1.4049199 | - |
dc.identifier.pmid | 34043760 | - |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q3 | - |
item.openairetype | Article | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 03.10. Department of Mechanical Engineering | - |
Appears in Collections: | Mechanical Engineering / Makina Mühendisliği PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
bio_143_04_044504.pdf | 2.21 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
16
checked on Dec 27, 2024
WEB OF SCIENCETM
Citations
12
checked on Dec 28, 2024
Page view(s)
4,072
checked on Dec 30, 2024
Download(s)
94
checked on Dec 30, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.