Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/11818
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMihçin, Şenay-
dc.contributor.authorÇıklaçandır, Samet-
dc.contributor.authorKoçak, Mertcan-
dc.contributor.authorTosun, Aliye-
dc.date.accessioned2021-12-02T18:16:15Z-
dc.date.available2021-12-02T18:16:15Z-
dc.date.issued2021-
dc.identifier.issn0148-0731-
dc.identifier.issn1528-8951-
dc.identifier.urihttps://doi.org/10.1115/1.4049199-
dc.identifier.urihttps://hdl.handle.net/11147/11818-
dc.description.abstractHuman motion capture (MOCAP) systems are vital while determining the loads occurring at the joints. Most of the clinical MOCAP systems are very costly, requiring investment and infrastructure. Therefore, alternative technologies are in demand. In this study, a novel markerless wearable MOCAP system was assessed for its compatibility with a biomechanical modeling software. To collect evidence, experiments were designed in two stages for quantifying the range of motion (ROM) of the hip joint, in vitro and in vivo. Three constrained single-plane motions-abduction/adduction, flexion/extension, and internal/external rotation movements of the active leg-were analyzed. The data were collected from 14 healthy volunteers, using the wearable system and a medical grade optoelectronic MOCAP system simultaneously and compared against. For the in vitro study, the root-mean-square error (RMSE) for the abduction/adduction motion of the hip joint was calculated as 0.11deg/0.30deg and 0.11deg/0.09deg, respectively, for the wearable and the opto-electronic system. The in vivo Bland-Altman plots showed that the two system data are comparable. The simulation software is found compatible to run the simulations in offline mode. The wearable system could be utilized in the field of biomechanics software for running the kinetic simulations. The results demonstrated that the wearable system could be an alternative in the field of biomechanics based on the evidence collected.en_US
dc.description.sponsorshipThis research received a funding from Katip Celebi University (Scientific Research Project No. 2019-GAP-MUMF-0015). We would like to thank IKCU Mechatronics Department Faculty Members for allowing us to use their OptiTrack System and laboratory. We would like to thank Ph.D. student Mr. Serkan Cizmecioullar (Electric and Electronics Dept, Istanbul University, Turkey) for his support. We would like to acknowledge the support of Rokoko Team (Rokoko, Copenhagen, Denmark), with their technical support for this research. We also like to thank Professor Dr. James Shippen and Dr. Barbara May, in making the required changes for BoB (BoB, Coventry, UK) to be compatible with the Smartsuit Pro system.en_US
dc.language.isoenen_US
dc.publisherASMEen_US
dc.relation.ispartofJournal of Biomechanical Engineeringen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMOCAPen_US
dc.subjectMotion analysisen_US
dc.subjectHuman motion capture systemsen_US
dc.subjectLower bodyen_US
dc.subjectWearable MOCAPen_US
dc.subjectVerificationen_US
dc.subjectISO13485en_US
dc.titleWearable motion capture system evaluation for biomechanical studies for hip jointsen_US
dc.typeArticleen_US
dc.authorid0000-0001-5077-8927-
dc.institutionauthorMihçin, Şenay-
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume143en_US
dc.identifier.issue4en_US
dc.identifier.wosWOS:000626080400016en_US
dc.identifier.scopus2-s2.0-85107253680en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1115/1.4049199-
dc.identifier.pmid34043760en_US
dc.identifier.wosqualityQ4-
dc.identifier.scopusqualityQ3-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.fulltextWith Fulltext-
item.languageiso639-1en-
item.grantfulltextopen-
item.openairetypeArticle-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
PubMed İndeksli Yayınlar Koleksiyonu / PubMed Indexed Publications Collection
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
bio_143_04_044504.pdf2.21 MBAdobe PDFView/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

10
checked on Apr 5, 2024

WEB OF SCIENCETM
Citations

9
checked on Mar 30, 2024

Page view(s)

3,914
checked on Apr 15, 2024

Download(s)

4
checked on Apr 15, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.