dc.description.abstract | This study examines the performance of attached prismatic panels, which have shading capability, in a side-lit deep plan room to find out the least possible WWR value in relation to room depth satisfying the required daylight availability. The methodology is based on simulating a base model in Relux and testing it with alternative models composed of incrementally defined WWR and room depth values. In accordance with minimum IES requirements, the most satisfying sDA value was found to be 48.54 % in a room of 12 m depth with 67 % WWR. An sDA of 51.59 % and 59.26 % was achieved in a room of 9m depth with 43 % WWR and 6m depth with 30 % WWR, respectively. The least ASE values were obtained with the least WWR alternative of 30 % in all room depths. This study presents a new approach with the consideration of innovative daylight redirecting systems to propose revisions for the requirements mentioned in standards about daylight in buildings but based on conventional fenestration systems. © 2020, LLC Editorial of Journal ""Light Technik"". All rights reserved. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Znack Publishing House | en_US |
dc.relation.ispartof | Light and Engineering | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Daylight | en_US |
dc.subject | Prismatic panels | en_US |
dc.subject | Room depth | en_US |
dc.subject | Windows | en_US |
dc.title | Applicability of a prismatic panel to optimize window size and depth of a south-facing room for a better daylight performance | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Köşe, Büşra | - |
dc.institutionauthor | Kazanasmaz, Zehra Tuğçe | - |
dc.department | İzmir Institute of Technology. Architecture | en_US |
dc.identifier.volume | 28 | en_US |
dc.identifier.issue | 4 | en_US |
dc.identifier.startpage | 63 | en_US |
dc.identifier.endpage | 67 | en_US |
dc.identifier.wos | WOS:000620643000004 | en_US |
dc.identifier.scopus | 2-s2.0-85095443291 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.33383/2019-038 | - |
dc.relation.doi | 10.33383/2019-038 | en_US |
dc.coverage.doi | 10.33383/2019-038 | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q4 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 02.02. Department of Architecture | - |
Appears in Collections: | Architecture / Mimarlık Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
2019_kose_kmaz_LE_rev.pdf | 603.95 kB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
6
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
6
checked on Nov 16, 2024
Page view(s)
816
checked on Nov 18, 2024
Download(s)
466
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.