Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/9863
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Karaçalı, Bilge | - |
dc.date.accessioned | 2021-01-24T18:28:50Z | - |
dc.date.available | 2021-01-24T18:28:50Z | - |
dc.date.issued | 2011 | - |
dc.identifier.isbn | 978-145770463-5 | - |
dc.identifier.uri | https://doi.org/10.1109/SIU.2011.5929612 | - |
dc.identifier.uri | https://hdl.handle.net/11147/9863 | - |
dc.description.abstract | In this study, automatic identification of landmarks was carried out on real double-echo PD/T2 Magnetic Resonance images for use in multi-modality deformable image registration algorithms. To this end, the corner points of the PD-weighted Magnetic Resonance image selected as the reference image were identified at varying fields of view and used as landmark candidates after eliminating the repeated points and those at close proximity. Next, the matching performances of these candidates were determined by invoking a localization algorithm that optimizes information theoretic point similarity measures derived earlier after random initialization at varying distances and directions. In consideration to the best performing point similarity measures and neighborhood radii at landmarks providing successful localization, the mutual information-based point similarity measure evaluated over large neighborhoods was preferred at a conspicuously higher rate than the other alternatives. © 2011 IEEE. | en_US |
dc.language.iso | tr | en_US |
dc.publisher | IEEE | en_US |
dc.relation | Farklı Kontrastlı Medikal Görüntülerin Bilgi Teorisi Kaynaklı Nokta Benzerliği Ölçütleriyle Elastik Olarak Hizalanması | - |
dc.relation.ispartof | 2011 IEEE 19th Signal Processing and Communications Applications Conference, SIU 2011 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Image matching | en_US |
dc.subject | Medical imaging | en_US |
dc.subject | Magnetic resonance imaging | en_US |
dc.title | Farklı kontrastlı medi̇kal görüntülerde elasti̇k hi̇zalama i̇çi̇n ni̇rengi̇ noktalarının beli̇rlenmesi̇ ve sınanması | en_US |
dc.title.alternative | Identification and evaluation of landmarks for deformable alignment of multi-modality medical images | - |
dc.type | Conference Object | en_US |
dc.institutionauthor | Karaçalı, Bilge | - |
dc.department | İzmir Institute of Technology. Electrical and Electronics Engineering | en_US |
dc.identifier.startpage | 158 | en_US |
dc.identifier.endpage | 161 | en_US |
dc.identifier.scopus | 2-s2.0-79960393057 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1109/SIU.2011.5929612 | - |
dc.relation.doi | 10.1109/SIU.2011.5929612 | en_US |
dc.coverage.doi | 10.1109/SIU.2011.5929612 | en_US |
dc.relation.grantno | 1.08E+251 | - |
dc.identifier.wosquality | N/A | - |
dc.identifier.scopusquality | N/A | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | open | - |
item.cerifentitytype | Publications | - |
item.fulltext | With Fulltext | - |
item.openairetype | Conference Object | - |
item.languageiso639-1 | tr | - |
crisitem.author.dept | 03.05. Department of Electrical and Electronics Engineering | - |
Appears in Collections: | Electrical - Electronic Engineering / Elektrik - Elektronik Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Identification.pdf | 664.09 kB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
202
checked on Nov 25, 2024
Download(s)
80
checked on Nov 25, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.