Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/9850
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Erdoğmuş, Abdullah Berkan | - |
dc.contributor.author | Mobedi, Moghtada | - |
dc.contributor.author | Özerdem, Barış | - |
dc.date.accessioned | 2021-01-24T18:28:46Z | - |
dc.date.available | 2021-01-24T18:28:46Z | - |
dc.date.issued | 2007 | - |
dc.identifier.isbn | 978-888988408-9 | - |
dc.identifier.uri | https://hdl.handle.net/11147/9850 | - |
dc.description | 20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, ECOS 2007, Padova | en_US |
dc.description.abstract | In the present study, energy losses due to heat transmission and air leakage from outdoor located air handling unit and connection duct are investigated based on EN 1886 and NEN-EN 1507 standard. The EN 1886 standard classifies air handling unit according to heat transmission and air leakage, while NEN-EN 1507 standard specify air leakages of rectangular ducts. In this study, air leakage and heat transmission fluxes for three cities in different regions of Turkey are determined and the economical value of energy losses for a building located in the city of Izmir and services 24 hours is calculated. The ambient air temperatures are taken from Turkish State Meteorological Service. The daily average values are considered for ambient temperature. The energy losses are determined for the variable and constant supply temperatures. Tables and charts are provided to show the variation of energy losses due to transmission and air leakage for the whole year. The total amounts of heat transmission and air leakage energy losses for different classes of air handling unit and connection duct are compared and discussed. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Universita degli Studi di Padova | en_US |
dc.relation.ispartof | ECOS 2007 - Proceedings of the 20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Air duct | en_US |
dc.subject | Air-handling unit | en_US |
dc.subject | Energy loss | en_US |
dc.title | Energy losses from outdoor located air handling unit and connection duct | en_US |
dc.type | Conference Object | en_US |
dc.institutionauthor | Erdoğmuş, Abdullah Berkan | - |
dc.institutionauthor | Mobedi, Moghtada | - |
dc.institutionauthor | Özerdem, Barış | - |
dc.department | İzmir Institute of Technology. Mechanical Engineering | en_US |
dc.identifier.volume | 2 | en_US |
dc.identifier.startpage | 1173 | en_US |
dc.identifier.endpage | 1181 | en_US |
dc.identifier.scopus | 2-s2.0-84930984762 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
local.message.claim | 2022-06-06T10:04:27.265+0300 | * |
local.message.claim | |rp01977 | * |
local.message.claim | |submit_approve | * |
local.message.claim | |dc_contributor_author | * |
local.message.claim | |None | * |
dc.identifier.wosquality | N/A | - |
dc.identifier.scopusquality | N/A | - |
item.fulltext | No Fulltext | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.languageiso639-1 | en | - |
item.grantfulltext | none | - |
item.openairetype | Conference Object | - |
item.cerifentitytype | Publications | - |
crisitem.author.dept | 03.10. Department of Mechanical Engineering | - |
crisitem.author.dept | 03.10. Department of Mechanical Engineering | - |
Appears in Collections: | Mechanical Engineering / Makina Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.