dc.description20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systems, ECOS 2007, Padovaen_US
dc.description.abstractIn the present study, energy losses due to heat transmission and air leakage from outdoor located air handling unit and connection duct are investigated based on EN 1886 and NEN-EN 1507 standard. The EN 1886 standard classifies air handling unit according to heat transmission and air leakage, while NEN-EN 1507 standard specify air leakages of rectangular ducts. In this study, air leakage and heat transmission fluxes for three cities in different regions of Turkey are determined and the economical value of energy losses for a building located in the city of Izmir and services 24 hours is calculated. The ambient air temperatures are taken from Turkish State Meteorological Service. The daily average values are considered for ambient temperature. The energy losses are determined for the variable and constant supply temperatures. Tables and charts are provided to show the variation of energy losses due to transmission and air leakage for the whole year. The total amounts of heat transmission and air leakage energy losses for different classes of air handling unit and connection duct are compared and discussed.en_US
dc.language.isoenen_US
dc.publisherUniversita degli Studi di Padovaen_US
dc.relation.ispartofECOS 2007 - Proceedings of the 20th International Conference on Efficiency, Cost, Optimization, Simulation and Environmental Impact of Energy Systemsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAir ducten_US
dc.subjectAir-handling uniten_US
dc.subjectEnergy lossen_US
dc.titleEnergy losses from outdoor located air handling unit and connection ducten_US
dc.typeConference Objecten_US
dc.institutionauthorErdoğmuş, Abdullah Berkan-
dc.institutionauthorMobedi, Moghtada-
dc.institutionauthorÖzerdem, Barış-
dc.departmentİzmir Institute of Technology. Mechanical Engineeringen_US
dc.identifier.volume2en_US
dc.identifier.startpage1173en_US
dc.identifier.endpage1181en_US
dc.identifier.scopus2-s2.0-84930984762en_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
local.message.claim2022-06-06T10:04:27.265+0300*
local.message.claim|rp01977*
local.message.claim|submit_approve*
local.message.claim|dc_contributor_author*
local.message.claim|None*
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityN/A-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
item.grantfulltextnone-
item.openairetypeConference Object-
item.cerifentitytypePublications-
crisitem.author.dept03.10. Department of Mechanical Engineering-
crisitem.author.dept03.10. Department of Mechanical Engineering-
Appears in Collections:Mechanical Engineering / Makina Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

586
checked on Nov 25, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.