Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/8825
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Toprak, Kasım | - |
dc.contributor.author | Ouedraogo, Kiswendsida Elias | - |
dc.date.accessioned | 2020-07-18T08:31:28Z | - |
dc.date.available | 2020-07-18T08:31:28Z | - |
dc.date.issued | 2020 | - |
dc.identifier.issn | 0363-907X | - |
dc.identifier.issn | 1099-114X | - |
dc.identifier.uri | https://doi.org/10.1002/er.5210 | - |
dc.identifier.uri | https://hdl.handle.net/11147/8825 | - |
dc.description.abstract | Thermal storage, low power tariff at night, and low nocturnal temperature can be used in synergy to reduce the cooling costs of the solar-powered absorption chiller cooling systems. This study aims to reduce the required cooling capacity of an absorption chiller (ACH) powered by a solar parabolic trough collector (PTC) and a backup fuel boiler by integrating thermal storage tanks. The thermal performance of the system is simulated for a building that is cooled for 14 h/day. The system uses 1000 m(2) PTC with 1020 kW ACH. Chilled water storage (CHWS) and cooling water storage (CWS) effects on the system performance for different operation hours per day of the ACH under Izmir (Turkey) and Phoenix (USA) weather conditions are analyzed. When the ACH operates 14 h/day as the load for both systems and both locations, the variations of the solar collector efficiency and the cooling load to heat input ratio remain less than 4% after the modifications. From the addition of CHWS to the reference system, a parametric study consisting of changing the ACH operation hours per day shows that the required cooling capacity of the ACH can be reduced to 34%. The capacity factor of the ACH is improved from its reference value of 41% up to 96%. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Wiley | en_US |
dc.relation.ispartof | International Journal of Energy Research | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Absorption chiller | en_US |
dc.subject | Capacity factor | en_US |
dc.subject | Thermal storage | en_US |
dc.title | Effect of storage tanks on solar-powered absorption chiller cooling system performance | en_US |
dc.type | Article | en_US |
dc.institutionauthor | Toprak, Kasım | - |
dc.institutionauthor | Ouedraogo, Kiswendsida Elias | - |
dc.department | İzmir Institute of Technology. Mechanical Engineering | en_US |
dc.identifier.volume | 44 | en_US |
dc.identifier.issue | 6 | en_US |
dc.identifier.startpage | 4366 | en_US |
dc.identifier.endpage | 4375 | en_US |
dc.identifier.wos | WOS:000523954300018 | en_US |
dc.identifier.scopus | 2-s2.0-85079718680 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1002/er.5210 | - |
dc.relation.doi | 10.1002/er.5210 | en_US |
dc.coverage.doi | 10.1002/er.5210 | en_US |
dc.identifier.wosquality | Q1 | - |
dc.identifier.scopusquality | Q1 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.10. Department of Mechanical Engineering | - |
Appears in Collections: | Mechanical Engineering / Makina Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
Intl J of Energy Research - 2020.pdf | 1.83 MB | Adobe PDF | View/Open |
CORE Recommender
SCOPUSTM
Citations
3
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
4
checked on Nov 9, 2024
Page view(s)
250
checked on Nov 18, 2024
Download(s)
112
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.