Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/6816
Full metadata record
DC FieldValueLanguage
dc.contributor.authorTuran, Gürsoy-
dc.date.accessioned2018-02-21T07:37:25Z-
dc.date.available2018-02-21T07:37:25Z-
dc.date.issued2014-
dc.identifier.citationTuran, G. (2014). Hybrid control of a 3-d structure by using semi-active dampers. In A. İlki, M. N. Fardis (Eds.), Seismic evaluation and rehabilitation of structures, (pp. 329-340). Cham: Springer. doi:10.1007/978-3-319-00458-7_18en_US
dc.identifier.issn1573-6059-
dc.identifier.urihttp://doi.org/10.1007/978-3-319-00458-7_18-
dc.identifier.urihttp://hdl.handle.net/11147/6816-
dc.description.abstractA base isolated three storey 3-D building is semi-actively controlled not to exceed the maximum allowable base displacement. Large displacements are likely to cause failure in the isolation system, and hence, failure in the superstructure is expected. If a base isolated structure is positioned next to a very long fault line, such as the North Anatolian Fault, the structure will mostly undergo far field type excitations. Near field effects will be seen less occasionally, but design considerations should be made to account for both types of excitations. In case of nearby seismic action, the isolated building should be smart enough to modify its isolation impedance to resist against large ground displacement and velocities. For this study, an isolated three storey building model together with four dampers, which are all placed at the base level, is considered. The dampers have controllable orifices (damping coefficients) and the magnitudes of these damping coefficients are assigned by using a linear quadratic regulator (LQR). During an earthquake excitation, the storey displacements and velocities are used as feedback in the calculation of the optimal control force that is producible by viscous dampers, at each time step. This force, however, is applied only at times when critical displacements and/or velocities occur. The performance of the set of controllers is presented via time simulations of the system for three recorded earthquakes. In addition, these records are time shifted five folds to see the effect of near field action. The results indicate that the control effectively reduces the maximum displacements of the isolation system, while maintaining a reasonable isolation to the superstructure.en_US
dc.language.isoenen_US
dc.publisherSpringer Verlagen_US
dc.relation.ispartofSeismic evaluation and rehabilitation of structuresen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSemi-active controlen_US
dc.subjectHybrid controlen_US
dc.subjectOptimum dampingen_US
dc.subjectEarthquake excitationen_US
dc.titleHybrid control of a 3-d structure by using semi-active dampersen_US
dc.typeBook Parten_US
dc.authoridTR115938en_US
dc.institutionauthorTuran, Gürsoy-
dc.departmentİzmir Institute of Technology. Civil Engineeringen_US
dc.identifier.volume26en_US
dc.identifier.startpage329en_US
dc.identifier.endpage340en_US
dc.identifier.scopus2-s2.0-84955282181en_US
dc.relation.publicationcategoryKitap Bölümü - Uluslararasıen_US
dc.identifier.doi10.1007/978-3-319-00458-7_18-
dc.relation.doi10.1007/978-3-319-00458-7_18en_US
dc.coverage.doi10.1007/978-3-319-00458-7_18en_US
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityQ4-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeBook Part-
crisitem.author.dept03.03. Department of Civil Engineering-
Appears in Collections:Civil Engineering / İnşaat Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
6816.pdfBookPart974.85 kBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Nov 15, 2024

Page view(s)

254
checked on Nov 18, 2024

Download(s)

194
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.