Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/6526
Title: Cyclic behavior of steel I-beams modified by a welded haunch and reinforced with GFRP
Authors: Eğilmez, Oğuz Özgür
Alkan, Deniz
Özdemir, Timur
Keywords: Existing steel buildings
Glass fiber reinforced polymers
Plastic local buckling
System stability
Seismic design
Publisher: Techno Press
Source: Eğilmez, O. Ö., Alkan, D., and Özdemir, T. (2009). Cyclic behavior of steel I-beams modified by a welded haunch and reinforced with GFRP. Steel and Composite Structures, 9(5), 419-444.
Abstract: Flange and web local buckling in beam plastic hinge regions of steel moment frames can prevent beam-column connections from achieving adequate plastic rotations under earthquake-induced forces. Reducing the flange-web slendemess ratios (FSR/WSR) of beams is the most effective way in mitigating local member buckling as stipulated in the latest seismic design specifications. However, existing steel moment frame buildings with beams that lack the adequate slendemess ratios set forth for new buildings are vulnerable to local member buckling and thereby system-wise instability prior to reaching the required plastic rotation capacities specified for new buildings. This paper presents results from a research study investigating the cyclic behavior of steel I-beams modified by a welded haunch at the bottom flange and reinforced with glass fiber reinforced polymers at the plastic hinge region. Cantilever I-sections with a triangular haunch at the bottom flange and flange slendemess ratios higher then those stipulated in current design specifications were analyzed under reversed cyclic loading. Beam sections with different depth/width and flange/web slendemess ratios (FSR/WSR) were considered. The effect of GFRP thickness, width, and length on stabilizing plastic local buckling was investigated. The FEA results revealed that the contribution of GFRP strips to mitigation of local buckling increases with increasing depth/width ratio and decreasing FSR and WSR. Provided that the interfacial shear strength of the steel/GFRP bond surface is at least 15 MPa, GFRP reinforcement can enable deep beams with FSR of 8-9 and WSR below - to maintain plastic rotations in the order of 0.02 radians without experiencing any local buckling.
URI: http://hdl.handle.net/11147/6526
http://doi.org/10.12989/scs.2009.9.5.419
ISSN: 1229-9367
1229-9367
1598-6233
Appears in Collections:Civil Engineering / İnşaat Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
6526.pdfMakale1.5 MBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

3
checked on Nov 9, 2024

Page view(s)

294
checked on Nov 18, 2024

Download(s)

294
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.