Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/5610
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Özşahin, İlker | - |
dc.contributor.author | Ünlü, Mehmet Zübeyir | - |
dc.date.accessioned | 2017-05-25T08:31:39Z | - |
dc.date.available | 2017-05-25T08:31:39Z | - |
dc.date.issued | 2014-03 | - |
dc.identifier.citation | Özşahin, I., and Ünlü, M.Z. (2014). Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors. Journal of Instrumentation, 9(3). doi:10.1088/1748-0221/9/03/C03055 | en_US |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | https://doi.org/10.1088/1748-0221/9/03/C03055 | - |
dc.identifier.uri | http://hdl.handle.net/11147/5610 | - |
dc.description.abstract | Breast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ∼ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer. | en_US |
dc.language.iso | en | en_US |
dc.publisher | IOP Publishing Ltd. | en_US |
dc.relation.ispartof | Journal of Instrumentation | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Gamma camera | en_US |
dc.subject | SPECT | en_US |
dc.subject | Computerized tomography | en_US |
dc.subject | Computed radiography | en_US |
dc.subject | X-ray mammography | en_US |
dc.title | Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors | en_US |
dc.type | Article | en_US |
dc.authorid | TR42462 | en_US |
dc.institutionauthor | Ünlü, Mehmet Zübeyir | - |
dc.department | İzmir Institute of Technology. Electrical and Electronics Engineering | en_US |
dc.identifier.volume | 9 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.wos | WOS:000336123200055 | en_US |
dc.identifier.scopus | 2-s2.0-84898899855 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1088/1748-0221/9/03/C03055 | - |
dc.relation.doi | 10.1088/1748-0221/9/03/C03055 | en_US |
dc.coverage.doi | 10.1088/1748-0221/9/03/C03055 | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q3 | - |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
crisitem.author.dept | 03.05. Department of Electrical and Electronics Engineering | - |
Appears in Collections: | Electrical - Electronic Engineering / Elektrik - Elektronik Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
4
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
4
checked on Oct 26, 2024
Page view(s)
3,852
checked on Nov 18, 2024
Download(s)
260
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.