Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/5610
Full metadata record
DC FieldValueLanguage
dc.contributor.authorÖzşahin, İlker-
dc.contributor.authorÜnlü, Mehmet Zübeyir-
dc.date.accessioned2017-05-25T08:31:39Z-
dc.date.available2017-05-25T08:31:39Z-
dc.date.issued2014-03-
dc.identifier.citationÖzşahin, I., and Ünlü, M.Z. (2014). Modeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectors. Journal of Instrumentation, 9(3). doi:10.1088/1748-0221/9/03/C03055en_US
dc.identifier.issn1748-0221-
dc.identifier.urihttps://doi.org/10.1088/1748-0221/9/03/C03055-
dc.identifier.urihttp://hdl.handle.net/11147/5610-
dc.description.abstractBreast cancer is the most common leading cause of cancer death among women. Positron Emission Tomography (PET) Mammography, also known as Positron Emission Mammography (PEM), is a method for imaging primary breast cancer. Over the past few years, PEMs based on scintillation crystals dramatically increased their importance in diagnosis and treatment of early stage breast cancer. However, these detectors have significant limitations like poor energy resolution resulting with false-negative result (missed cancer), and false-positive result which leads to suspecting cancer and suggests an unnecessary biopsy. In this work, a PEM scanner based on CdTe strip detectors is simulated via the Monte Carlo method and evaluated in terms of its spatial resolution, sensitivity, and image quality. The spatial resolution is found to be ∼ 1 mm in all three directions. The results also show that CdTe strip detectors based PEM scanner can produce high resolution images for early diagnosis of breast cancer.en_US
dc.language.isoenen_US
dc.publisherIOP Publishing Ltd.en_US
dc.relation.ispartofJournal of Instrumentationen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGamma cameraen_US
dc.subjectSPECTen_US
dc.subjectComputerized tomographyen_US
dc.subjectComputed radiographyen_US
dc.subjectX-ray mammographyen_US
dc.titleModeling and simulation of Positron Emission Mammography (PEM) based on double-sided CdTe strip detectorsen_US
dc.typeArticleen_US
dc.authoridTR42462en_US
dc.institutionauthorÜnlü, Mehmet Zübeyir-
dc.departmentİzmir Institute of Technology. Electrical and Electronics Engineeringen_US
dc.identifier.volume9en_US
dc.identifier.issue3en_US
dc.identifier.wosWOS:000336123200055en_US
dc.identifier.scopus2-s2.0-84898899855en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1088/1748-0221/9/03/C03055-
dc.relation.doi10.1088/1748-0221/9/03/C03055en_US
dc.coverage.doi10.1088/1748-0221/9/03/C03055en_US
dc.identifier.wosqualityQ4-
dc.identifier.scopusqualityQ3-
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeArticle-
crisitem.author.dept03.05. Department of Electrical and Electronics Engineering-
Appears in Collections:Electrical - Electronic Engineering / Elektrik - Elektronik Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File Description SizeFormat 
5610.pdfMakale1.17 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

SCOPUSTM   
Citations

4
checked on Nov 15, 2024

WEB OF SCIENCETM
Citations

4
checked on Oct 26, 2024

Page view(s)

3,852
checked on Nov 18, 2024

Download(s)

260
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.