Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/3607
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Başaran, Tahsin | en |
dc.contributor.author | Akdemir, Manolya | - |
dc.date.accessioned | 2014-07-22T13:51:56Z | - |
dc.date.available | 2014-07-22T13:51:56Z | - |
dc.date.issued | 2013 | en |
dc.identifier.uri | http://hdl.handle.net/11147/3607 | - |
dc.description | Thesis (Master)--Izmir Institute of Technology, Energy Engineering, Izmir, 2013 | en |
dc.description | Includes bibliographical references (leaves: 97-99) | en |
dc.description | Text in English; Abstract: Turkish and English | en |
dc.description | xii, 99 leaves | en |
dc.description.abstract | Primary objective of this thesis is to find out energy level of an existing building and investigate the opportunities in order to improve its energy level by retrofitting the envelope and using exergy analysis methods on alternative HVAC systems. To arrive at the objective, an existing building, Izmir Institute of Technology (IZTECH), Faculty of Architecture Block C, has been used as the case study. This building cannot comply with TS-825 standards (Turkish Standard Assessment) and energy efficiency parameters due to the building components and HVAC systems. According to the recorded outdoor climatic conditions, the building was modeled and simulated; and the retrofitting was tried in EDSL-TAS energy simulation software package. Simultaneously, exergy analyses for the situations before and after refurbishments were employed. Different from the most studies in the literature, this thesis carries out the exergy analyses using the dynamic data instead of the steady state ones. By the evaluation of these analyses together, energy level and the climatic comfort of the building have been seriously increased and the building’s loads have been decreased with ratio of 69.42% for heating system and 34.4% for cooling system after retrofitting. In exergy calculations, exergy efficiency of the system ranges between 2-14% with existing HVAC applications, 4-18% with Air Source Heat Pump (ASHP) and 8-21% with Ground Source Heat Pump (GSHP). | en |
dc.language.iso | en | en_US |
dc.publisher | Izmir Institute of Technology | en |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject.lcsh | Buildings--Energy conservation | en |
dc.subject.lcsh | Exergy | en |
dc.title | Dynamic energy and exergy analysis of an existing building in IZTECH | en_US |
dc.type | Master Thesis | en_US |
dc.institutionauthor | Akdemir, Manolya | - |
dc.department | Thesis (Master)--İzmir Institute of Technology, Energy Systems Engineering | en_US |
dc.relation.publicationcategory | Tez | en_US |
item.fulltext | With Fulltext | - |
item.grantfulltext | open | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Master Thesis | - |
Appears in Collections: | Master Degree / Yüksek Lisans Tezleri |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
10011084.pdf | MasterThesis | 7.93 MB | Adobe PDF | View/Open |
CORE Recommender
Page view(s)
210
checked on Nov 18, 2024
Download(s)
128
checked on Nov 18, 2024
Google ScholarTM
Check
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.