Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/3257
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorİlken, Zaferen
dc.contributor.authorGediz, Gamze-
dc.date.accessioned2014-07-22T13:51:11Z-
dc.date.available2014-07-22T13:51:11Z-
dc.date.issued2004en
dc.identifier.urihttp://hdl.handle.net/11147/3257-
dc.descriptionThesis (Master)--Izmir Institute of Technology, Mechanical Engineering, Izmir, 2004en
dc.descriptionIncludes bibliographical references (leaves: 96)en
dc.descriptionText in English; Abstract: Turkish and Englishen
dc.descriptionxiv, 148 leavesen
dc.description.abstractIzmir Institute of Technology (IZTECH), founded in 1992, is the third state university of Izmir. The campus area has the renewable energy sources of several kinds. The aim of this thesis is to design and optimize a building, which produce its own energy by using these sources.Gülbahçe Zero Energy Building (GUZEB) is designed as a library and a gallery, and to be used for symposiums and special day meetings. 32oC geothermal water that is from the ancient cave, which is located in campus area and close to the location of the building, will be used for heating and to meet the hot water requirement of the building. Floor heating system considered being the best heating option with 32oC water source. Necessary pipe length for floor heating system is found by using the software FLUENT.Necessary cooling load is calculated in two different ways by with and without hourly load distribution. With hourly load distribution cooling load calculation is made by using Alarko-Carrier .s HVAC Design Hourly Analysis Program.Additionally, energy storage method is recommended for the cooling plant, which will meet the cooling load. With this method, smaller cooling plant can be chosen instead of choosing cooling plant, which meets the load of symposium days or special day meetings that both are rare. Because of this, electrical load of the cooling plant considered to be lower.Silica-aerogel and many different isolation materials are used in the design of building.s isolation. Fiber lighting is recommended to decrease the lighting load of the building and with automatic controlled curtains and panels; daylight can be controlled during the summer days. So, electric consumption of the building can be tried to be decrease. The wind speed of the location is 5-7 m/s. Electric demand can be met with the photovoltaic panels and wind turbine that will be located in suitable position.en
dc.language.isoenen_US
dc.publisherIzmir Institute of Technologyen
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.lccTJ163.5.B84 .G29 2004en
dc.subject.lcshBuildings--Energy conservation--Izmir(Turkey)en
dc.subject.lcshSolar buildings--Turkey--Design and constructionen
dc.titleDesign and optimization of a zero energy buildingen_US
dc.typeMaster Thesisen_US
dc.institutionauthorGediz, Gamze-
dc.departmentThesis (Master)--İzmir Institute of Technology, Mechanical Engineeringen_US
dc.relation.publicationcategoryTezen_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
item.languageiso639-1en-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.cerifentitytypePublications-
item.openairetypeMaster Thesis-
Appears in Collections:Master Degree / Yüksek Lisans Tezleri
Files in This Item:
File Description SizeFormat 
T000448.pdfMasterThesis2.08 MBAdobe PDFThumbnail
View/Open
Show simple item record



CORE Recommender

Page view(s)

236
checked on Nov 18, 2024

Download(s)

96
checked on Nov 18, 2024

Google ScholarTM

Check





Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.