Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/2582
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Demir, Durmuş Ali | - |
dc.contributor.author | CMS Collaboration | - |
dc.date.accessioned | 2016-12-06T13:46:13Z | - |
dc.date.available | 2016-12-06T13:46:13Z | - |
dc.date.issued | 2010 | - |
dc.identifier.citation | Chatrchyan, S., Khachatryan, V., Sirunyan, A. M., Adam. W., Arnold, B., ...CMS Collaboration (2010). Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons. Journal of Instrumentation, 5(3). doi:10.1088/1748-0221/5/03/T03008 | en_US |
dc.identifier.issn | 1748-0221 | - |
dc.identifier.uri | http://doi.org/10.1088/1748-0221/5/03/T03008 | - |
dc.identifier.uri | http://hdl.handle.net/11147/2582 | - |
dc.description.abstract | During autumn 2008, the Silicon Strip Tracker was operated with the full CMS experiment in a comprehensive test, in the presence of the 3.8 T magnetic field produced by the CMS superconducting solenoid. Cosmic ray muons were detected in the muon chambers and used to trigger the readout of all CMS sub-detectors. About 15 million events with a muon in the tracker were collected. The efficiency of hit and track reconstruction were measured to be higher than 99% and consistent with expectations from Monte Carlo simulation. This article details the commissioning and performance of the Silicon Strip Tracker with cosmic ray muons. © 2010 IOP Publishing Ltd and SISSA. | en_US |
dc.description.sponsorship | CERN and other CMS Institutes; TÜBİTAK and TAEK | en_US |
dc.language.iso | en | en_US |
dc.publisher | IOP Publishing Ltd. | en_US |
dc.relation.ispartof | Journal of Instrumentation | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Large detector systems | en_US |
dc.subject | Particle tracking detectors | en_US |
dc.subject | Solid-state detectors | en_US |
dc.subject | Silicon tracker | en_US |
dc.subject | Compact Muon Solenoid | en_US |
dc.subject | Large Hadron Collider (LHC) | en_US |
dc.title | Commissioning and performance of the CMS silicon strip tracker with cosmic ray muons | en_US |
dc.type | Article | en_US |
dc.authorid | TR1918 | en_US |
dc.institutionauthor | Demir, Durmuş Ali | - |
dc.department | İzmir Institute of Technology. Physics | en_US |
dc.identifier.volume | 5 | en_US |
dc.identifier.issue | 3 | en_US |
dc.identifier.wos | WOS:000280524100025 | en_US |
dc.identifier.scopus | 2-s2.0-78650529467 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1088/1748-0221/5/03/T03008 | - |
dc.relation.doi | 10.1088/1748-0221/5/03/T03008 | en_US |
dc.coverage.doi | 10.1088/1748-0221/5/03/T03008 | en_US |
dc.identifier.wosquality | Q4 | - |
dc.identifier.scopusquality | Q3 | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.fulltext | With Fulltext | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.grantfulltext | open | - |
crisitem.author.dept | 04.05. Department of Pyhsics | - |
Appears in Collections: | Physics / Fizik Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
SCOPUSTM
Citations
45
checked on Nov 29, 2024
WEB OF SCIENCETM
Citations
57
checked on Nov 9, 2024
Page view(s)
270
checked on Dec 2, 2024
Download(s)
166
checked on Dec 2, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.