Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/2581
Title: Time Reconstruction and Performance of the Cms Electromagnetic Calorimeter
Authors: Demir, Durmuş Ali
Karapınar, Güler
Keywords: Calorimeters
Large detector systems
Compact Muon Solenoid
Large Hadron Collider (LHC)
Electromagnetic calorimeter
Publisher: IOP Publishing Ltd.
Source: Chatrchyan, S., Khachatryan, V., Sirunyan, A. M., Adam. W., Arnold, B., ...CMS Collaboration (2010). Time reconstruction and performance of the CMS electromagnetic calorimeter. Journal of Instrumentation, 5(3). doi:10.1088/1748-0221/5/03/T03011
Abstract: The resolution and the linearity of time measurements made with the CMS electromagnetic calorimeter are studied with samples of data from test beam electrons, cosmic rays, and beam-produced muons. The resulting time resolution measured by lead tungstate crystals is better than 100 ps for energy deposits larger than 10 GeV. Crystal-to-crystal synchronization with a precision of 500 ps is performed using muons produced with the first LHC beams in 2008. © 2010 IOP Publishing Ltd and SISSA.
URI: http://doi.org/10.1088/1748-0221/5/03/T03011
http://hdl.handle.net/11147/2581
ISSN: 1748-0221
Appears in Collections:Physics / Fizik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
2581.pdfMakale534.24 kBAdobe PDFThumbnail
View/Open
Show full item record



CORE Recommender

SCOPUSTM   
Citations

67
checked on May 2, 2025

WEB OF SCIENCETM
Citations

49
checked on May 2, 2025

Page view(s)

306
checked on Apr 28, 2025

Download(s)

228
checked on Apr 28, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.