Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/15234
Title: Sleep Quality: Design of Bedroom Ventilation and Evaluation Within the Scope of Current Standards
Authors: Cobanoglu, Nur
Karadeniz, Ziya Haktan
Sofuoglu, Sait Cemil
Toksoy, Macit
Keywords: Sleep Quality
Indoor Air Quality
Ventilation Rate Procedure
Indoor Air Quality Procedure
Ventilation
Publisher: Elsevier Science Sa
Abstract: Indoor air pollution is one of the leading environmental risks to public health considering people now spending nearly 90 % of their day in indoor environments. A significant portion of this time indoors is devoted to sleeping, making it crucial to address the impact of indoor environmental conditions on sleep quality. International ventilation standards such as ASHRAE and CEN, as well as country-specific guidelines, offer valuable recommendations for ventilation design in residential buildings, including bedrooms. This study aims to evaluate the importance of determining ventilation rates in sleeping spaces using Indoor Air Quality Procedure (IAQP) compared to Ventilation Rate Procedure (VRP) in accordance with current standards. Here, the IAQP approach for determining air flow rate is based on the CO2 balance by maintaining CO2 levels in any sleeping environment below specified upper limits of 750 ppm and 1000 ppm. This study focused on the adult population, which forms the majority of society, with analyses conducted for both single and double occupancy sleeping conditions. The volume of environment where ventilation is not required during sleep (Vf) is inaccessible in conventional sleeping environments (10-21.6 m3 per person). Therefore, proper ventilation is of great importance for any sleeping space that is smaller than the Vf. The results of the analyses show that for the conventional sleeping volumes, CO2 levels reach 750 ppm (upper limit for comfortable sleep) in the first hour and increase to the disturbed sleep zone in about 2 h. Additionally, a chart outlining the necessary ventilation flow rates is suggested for maintaining maximum CO2 concentrations of 750 and 1000 ppm during different sleep durations and in various sleeping environments with varying volumes. Finally, the ventilation rates determined based on unit area and/or occupancy levels in standards (referred to as VRP) may not always be adequate or may be excessive in order to maintain CO2 concentrations below the recommended limits of 750 and 1000 ppm. It is advised to utilize demand-controlled ventilation by considering the system design as recommended by IAQP.
Description: Sofuoglu, Sait C./0000-0001-6990-0275; Karadeniz, Z. Haktan/0000-0001-7850-7942
URI: https://doi.org/10.1016/j.enbuild.2024.115073
ISSN: 0378-7788
1872-6178
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

Page view(s)

66
checked on Feb 17, 2025

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.