Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/15200
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Aktas, Burak | - |
dc.contributor.author | Ates, Doga Deniz | - |
dc.contributor.author | Duzyel, Okan | - |
dc.contributor.author | Gumus, Abdurrahman | - |
dc.date.accessioned | 2024-12-25T20:49:30Z | - |
dc.date.available | 2024-12-25T20:49:30Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 1868-8071 | - |
dc.identifier.issn | 1868-808X | - |
dc.identifier.uri | https://doi.org/10.1007/s13042-024-02485-w | - |
dc.identifier.uri | https://hdl.handle.net/11147/15200 | - |
dc.description.abstract | Deep learning models, integral components of contemporary technological landscapes, exhibit enhanced learning capabilities with larger datasets. Traditional data augmentation techniques, while effective in generating new data, have limitations, especially in fields like ocular disease diagnosis. In response, alternative augmentation approaches, including the utilization of generative AI, have emerged. In our study, we employed a diffusion-based model (Stable Diffusion) to synthesize data by faithfully recreating crucial vascular structures in the retina, vital for detecting eye diseases by using the Ocular Disease Intelligent Recognition dataset. Our goal was to augment retinography images for ocular disease diagnosis using diffusion-based models, optimizing the outputs of the fine-tuned Stable Diffusion model, and ensuring the generated data closely resembles real-world scenarios. This strategic approach resulted in improved performance in classification models and augmentation outperformed traditional methods, exhibiting high precision rates ranging from 85% to 76.2% and recall values of 86%, and 75% for 5 classes. Beyond performance enhancement, we demonstrated that the inclusion of synthetic data, coupled with data reduction using the t-SNE method, effectively addressed dataset imbalance. As a result of synthetic data addition, notable increases of 3.4% in the precision metric and 12.8% in the recall metric were observed in the 7-class case. Strategically synthesizing data addressed underrepresented classes, creating a balanced dataset for comprehensive model learning. Surpassing performance improvements, this approach underscores synthetic data's ability to overcome the limitations of traditional methods, particularly in sensitive medical domains like ocular disease diagnosis, ensuring accurate classification. The codes of the study will be shared on GitHub in a way that benefits everyone interested: https://github.com/miralab-ai/generative-data-augmentation. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer Heidelberg | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Image classification | en_US |
dc.subject | Data augmentation | en_US |
dc.subject | Diffusion-based models | en_US |
dc.subject | t-SNE | en_US |
dc.subject | Medical image synthesis | en_US |
dc.subject | Dataset imbalance | en_US |
dc.title | Diffusion-Based Data Augmentation Methodology for Improved Performance in Ocular Disease Diagnosis Using Retinography Images | en_US |
dc.type | Article | en_US |
dc.department | Izmir Institute of Technology | en_US |
dc.identifier.wos | WOS:001375441800001 | - |
dc.identifier.scopus | 2-s2.0-85212076581 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1007/s13042-024-02485-w | - |
dc.authorscopusid | 59472597500 | - |
dc.authorscopusid | 59473279900 | - |
dc.authorscopusid | 58135677500 | - |
dc.authorscopusid | 35315599800 | - |
dc.identifier.wosquality | Q2 | - |
dc.identifier.scopusquality | Q1 | - |
dc.description.woscitationindex | Science Citation Index Expanded | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.grantfulltext | none | - |
item.openairetype | Article | - |
item.languageiso639-1 | en | - |
item.cerifentitytype | Publications | - |
item.fulltext | No Fulltext | - |
crisitem.author.dept | 03.05. Department of Electrical and Electronics Engineering | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.