Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/14729
Full metadata record
DC FieldValueLanguage
dc.contributor.authorUçar,Ö.I.-
dc.contributor.authorAltuner,H.M.-
dc.contributor.authorGünyüz,M.-
dc.contributor.authorDündar,M.M.-
dc.contributor.authorÖzdemir,D.-
dc.date.accessioned2024-09-24T15:50:10Z-
dc.date.available2024-09-24T15:50:10Z-
dc.date.issued2014-
dc.identifier.isbn978-111888843-8-
dc.identifier.isbn978-111888908-4-
dc.identifier.urihttps://doi.org/10.1002/9781118888438.ch71-
dc.identifier.urihttps://hdl.handle.net/11147/14729-
dc.description.abstractThe surface characteristics of rolled aluminum products such as sheets and foils are strongly affected by the particular rolling process and the type of aluminum rolling oil compositions. After the rolling process, coiled aluminum sheets and foils undergoes annealing to form desired crystal structure and remove the rolling oil residues. Depending on the time and the temperature that rolled aluminum exposed for annealing, rolling oil residues are mostly removed from the coiled aluminum products but if there is any contamination in rolling oil due to hydraulic and gearing parts of the rolling systems these heavier oils are not easily evaporates from the aluminum surfaces especially inner parts of the coiled aluminum sheets and foils. These rolling oil contaminants create serious problems for the some specific applications of these aluminum products in certain industries such as automotive and coating as remaining thin oil layer prevents proper painting and coating. Therefore, it is very crucial for the rolling industry to be able to monitor the heavy oil contamination on the rolled products and determine the source of these contaminants .In this study, it was aimed to develop a nondestructive infrared spectroscopic method combined with chemometric multivariate calibration techniques for the quantitative determination of rolling oil residues and contaminants on the rolled aluminum products. To be able to generate multivariate calibration methods, an industrial elemental analysis system was adopted for the quantitative determination of heavy oil contaminants on the rolled aluminum products and these were used as reference values for infrared analysis of the same samples. In addition, apart from conventional use of elemental analysis systems for the total organic analysis, the raw data (raw chromatogram) obtained from elemental analysis was used to directly generate multivariate calibration models for each contaminant by using synthetically contaminated surfaces as the calibration samples. The results promised that elemental analysis can be used not just for the total organic content but also specifically to determine amount of each infrared spectroscopy with grazing angle spectra collection accessories can be used for nondestructive analysis of these contaminants. © 2014 The Minerals, Metals & Materials Society.en_US
dc.language.isoenen_US
dc.publisherWiley Blackwellen_US
dc.relation.ispartofLight Metals 2014en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAluminum rollingen_US
dc.subjectElemental analysisen_US
dc.subjectFTIRen_US
dc.subjectGenetic algorithmsen_US
dc.subjectMultivariate calibrationen_US
dc.subjectRolling oil additives and contaminantsen_US
dc.titleDetermination of Aluminum Rolling Oil and Machinery Oil Residues on Finished Aluminum Sheet and Foil Using Elemental Analysis and Fourier Transform Infrared Spectroscopy Coupled with Multivariate Calibrationen_US
dc.typeBook Parten_US
dc.departmentIzmir Institute of Technologyen_US
dc.identifier.volume9781118889084en_US
dc.identifier.startpage415en_US
dc.identifier.endpage420en_US
dc.identifier.scopus2-s2.0-84927976403-
dc.relation.publicationcategoryKitap Bölümü - Uluslararasıen_US
dc.identifier.doi10.1002/9781118888438.ch71-
dc.authorscopusid36136149200-
dc.authorscopusid37023083100-
dc.authorscopusid18634403300-
dc.authorscopusid59270099600-
dc.authorscopusid57212093641-
dc.identifier.wosqualityN/A-
dc.identifier.scopusqualityN/A-
item.fulltextNo Fulltext-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.openairetypeBook Part-
item.cerifentitytypePublications-
item.languageiso639-1en-
item.grantfulltextnone-
Appears in Collections:Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
Show simple item record



CORE Recommender

Page view(s)

2
checked on Oct 14, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.