Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/14696
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Sozmen, Eser Yildirim | - |
dc.contributor.author | Sozmen, Alper Baran | - |
dc.date.accessioned | 2024-09-24T15:48:32Z | - |
dc.date.available | 2024-09-24T15:48:32Z | - |
dc.date.issued | 2024 | - |
dc.identifier.issn | 0970-1915 | - |
dc.identifier.issn | 0974-0422 | - |
dc.identifier.uri | https://doi.org/10.1007/s12291-024-01253-5 | - |
dc.identifier.uri | https://hdl.handle.net/11147/14696 | - |
dc.description | Sozmen, Alper/0000-0002-2633-3837 | en_US |
dc.description.abstract | Food allergy and histamine intolerance (HI) are prevalent worldwide. Diamine oxidase (DAO) activity determination in serum is a promising approach for diagnosing HI. Despite the numerous methods that have been published for determining diamine. oxidase activity in serum, most of them have not been validated and have inherent limitations, such as interference and multi-step analysis. Our objective was to perform the analytical validation of a novel micro-spectrophotometric method for the determination of DAO activity in a routine clinical laboratory setting. In this study we determined DAO activity in serum using a 4-aminoantypirine (4-AAP) and 2,4,6 tribromo-3-hidroxybenzoic acid (TBHBA) combination as chromogen for the first time. Validation steps included determination of accuracy (recovery and linearity) and precision (within-run and between-run repeatability) following the Clinical and Laboratory Standards Institute protocols and the other guidelines. Reagent stability assessment at both 4 degrees C temperature and frozen (- 20 degrees C) after 4 h, 24 h, 72 h and a week storage were conducted. The optimum test conditions were determined as pH = 6.0, 37 degrees C, 55 mM Putrescine and 60 min. LOD and LOQ levels were found as 10.08 U/L and 30.56 U/L respectively. Coefficients of variation (CVs) for within-run and between-run precisions were 5.2%, 9.4% for the normal level and 2.6%, 2.2% for the high range, respectively. This reliable method for quantifying DAO activity in serum provides an optimal approach, offering rapid and straightforward performance in laboratories for clinical use. | en_US |
dc.description.sponsorship | KOSGEB (Small and Medium Enterprises Development Organization of Turkiye) [455S8] | en_US |
dc.description.sponsorship | The authors appreciated to KOSGEB (Small and Medium Enterprises Development Organization of Turkiye) [grant number: 455S8, 2021] for their financial support. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer india | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Diamine oxidase | en_US |
dc.subject | Histamine intolerance | en_US |
dc.subject | Food allergy | en_US |
dc.title | Validation of New Micro-spectrophotometric Method to Determine Diamine Oxidase Activity in Serum | en_US |
dc.type | Article | en_US |
dc.authorid | Sozmen, Alper/0000-0002-2633-3837 | - |
dc.department | Izmir Institute of Technology | en_US |
dc.identifier.wos | WOS:001276937900001 | - |
dc.identifier.scopus | 2-s2.0-85199644090 | - |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.identifier.doi | 10.1007/s12291-024-01253-5 | - |
dc.authorscopusid | 7004558658 | - |
dc.authorscopusid | 57201620092 | - |
dc.identifier.scopusquality | Q3 | - |
dc.description.woscitationindex | Emerging Sources Citation Index | - |
item.fulltext | No Fulltext | - |
item.grantfulltext | none | - |
item.languageiso639-1 | en | - |
item.openairecristype | http://purl.org/coar/resource_type/c_18cf | - |
item.cerifentitytype | Publications | - |
item.openairetype | Article | - |
Appears in Collections: | Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.