Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/14253
Full metadata record
DC FieldValueLanguage
dc.contributor.authorSaatcı, Selçuk-
dc.contributor.authorÇetin, Fatma Şirin-
dc.contributor.authorAloui, Sarra-
dc.contributor.authorNaseri, Jamalullah-
dc.date.accessioned2024-01-30T09:24:42Z-
dc.date.available2024-01-30T09:24:42Z-
dc.date.issued2024-
dc.identifier.issn0950-0618-
dc.identifier.issn1879-0526-
dc.identifier.urihttps://doi.org/10.1016/j.conbuildmat.2023.134190-
dc.identifier.urihttps://hdl.handle.net/11147/14253-
dc.description.abstractPerformance of hybrid fiber reinforced concrete (HyFRC) determined through standardized material tests usually correlates well with the structural performance. However, for thin panels, this correlation may be disturbed due to the fiber orientation and small crack surfaces, and more detailed investigations are required. In this study, effects of steel fiber type and ratio on the one-way bending behavior of HyFRC thin panels was investigated through concrete mixes obtained by using three different steel fiber types and polyvinyl alcohol (PVA) fibers. 45 dog bone shaped, notched specimens were cast and tested under direct tension to investigate the direct tension behavior of used HyFRC. Nine panels of 2500 x 500 x 50 mm in dimension were tested under three-point bending, and nine panels of 1240 x 500 x 50 mm in dimension were tested under four-point bending. An in-verse analysis to obtain crack width-stress variation in three-and four-point bending specimens was also per-formed and behavior of steel fiber reinforced concrete specimens with and without PVA addition were compared. It was found that steel fiber type and ratio was consistently the dominant factor for all types of tests on HyFRC specimens. Addition of PVA fibers in HyFRC specimens either resulted in a similar or worse behavior for direct tension and three-point bending compared to their steel fiber only counterparts. Adverse effect of PVA fibers was more pronounced in three-point bending tests. On the other hand, PVA addition had a more positive effect in four-point bending tests. Inverse analyses performed on three-point bending tests revealed that stress levels develop between crack surfaces in these thin panels were significantly lower compared to direct tension stress levels. However, under four-point bending, these tensile stresses were closer to direct tension stresses, especially for specimens with shorter steel fibers. Loading conditions were found to be an effective factor in the behavior of HyFRC thin panels.en_US
dc.description.sponsorshipPart of this work was financially supported by Izmir Institute of Technology Scientific Research Grant [2017IYTE68] . Some tests were conducted with the support of Integrated Research Centers at the Izmir Institute of Technology.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relationHibrit Fiberli Betonda Sinerji Etkisitr
dc.relation.ispartofConstruction and Building Materialsen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectHybrid fiber reinforced concreteen_US
dc.subjectSteel fibersen_US
dc.subjectPVA fibersen_US
dc.subjectThin panelsen_US
dc.subjectDirect tension behavioren_US
dc.subjectBending behavioren_US
dc.titleEffects of steel fiber type and ratio on the one-way bending behavior of hybrid fiber reinforced concrete thin panelsen_US
dc.typeArticleen_US
dc.authorid0000-0002-1149-2077-
dc.departmentİzmir Institute of Technology. Civil Engineeringen_US
dc.identifier.volume411en_US
dc.identifier.wosWOS:001125999500001en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.identifier.doi10.1016/j.conbuildmat.2023.134190-
dc.relation.grantno2017IYTE68-
dc.authorwosidSaatci, Selcuk/C-2557-2012-
item.grantfulltextembargo_20260101-
item.openairetypeArticle-
item.fulltextWith Fulltext-
item.cerifentitytypePublications-
item.openairecristypehttp://purl.org/coar/resource_type/c_18cf-
item.languageiso639-1en-
crisitem.author.dept03.03. Department of Civil Engineering-
crisitem.author.dept01. Izmir Institute of Technology-
crisitem.author.dept01. Izmir Institute of Technology-
Appears in Collections:Civil Engineering / İnşaat Mühendisliği
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection
Files in This Item:
File SizeFormat 
1-s2.0-S0950061823039089-main.pdf
  Until 2026-01-01
8.03 MBAdobe PDFView/Open    Request a copy
Show simple item record



CORE Recommender

Page view(s)

58
checked on May 6, 2024

Google ScholarTM

Check




Altmetric