Please use this identifier to cite or link to this item:
https://hdl.handle.net/11147/13989
Title: | Cold plate enabling air and liquid cooling simultaneously: Experimental study for battery pack thermal management and electronic cooling | Authors: | Coşkun, Turgay Çetkin, Erdal |
Keywords: | Hybrid thermal management Battery module Electric vehicle Lithium-ion battery Hybrid cold plate Electronic cooling |
Publisher: | Elsevier | Abstract: | The temperature of cells varies greatly during dis/charge while their performance and lifetime are greatly affected by this fluctuation. Elevated temperatures may yield battery fire due to thermal runaway as well they accelerate ageing and capacity fade of cells. Thermal management systems are a necessity for electric vehicles to extend the lifetime of battery cells and eliminate any fire risks, especially for fast dis/charging applications. Here, we document a hybrid cold plate with a working fluid(s) of sole air or liquid as well as both of them. Hybridization of air and liquid cooling promises to minimize energy consumption requirements during a charge/ discharge cycle by combining the benefits of both thermal management strategies if energy management is controlled accordingly. The temperature of each cell can be kept below 30 degrees C with the proposed hybrid cooling heat exchanger, and the temperature difference between the cells is reduced by 30 % relative to liquid cooling. The maximum temperatures are decreased by 18 % and 3 % in hybrid cooling when compared to air and water cooling, respectively. Furthermore, a step function combining various discharge rates (1C and 3C) was employed in experiments to mimic a realistic situation, i.e. variable C-rate rather than constant. The results show that the temperature of the battery cells can be kept below 30 degrees C with air cooling for variable discharge rate and the effect of contact resistance should not be overlooked for liquid cooling. Furthermore, the possible use of the proposed hybrid cold plates is surveyed in the cooling of electronic devices which produce more and continuous heat than cells. Therefore, three resistance heaters with a capacity of 50W are used in experiments as well. The results show that the proposed cold plates could be used in both electronics cooling and battery thermal management with a control algorithm to switch between sole working fluid and combination modes which could be developed based on the results of this paper. | URI: | https://doi.org/10.1016/j.ijheatmasstransfer.2023.124702 https://hdl.handle.net/11147/13989 |
ISSN: | 0017-9310 1879-2189 |
Appears in Collections: | Mechanical Engineering / Makina Mühendisliği Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection |
Files in This Item:
File | Size | Format | |
---|---|---|---|
1-s2.0-S0017931023008475-main.pdf Until 2025-01-01 | 5.54 MB | Adobe PDF | View/Open Request a copy |
CORE Recommender
SCOPUSTM
Citations
5
checked on Nov 15, 2024
WEB OF SCIENCETM
Citations
4
checked on Oct 26, 2024
Page view(s)
236
checked on Nov 18, 2024
Google ScholarTM
Check
Altmetric
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.