Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/13227
Title: Thermodynamic re-assessment of a geothermal binary power plant operated in a moderate-temperature geothermal field
Authors: Özcan, Zeynep
Gökçen Akkurt, Gülden
Keywords: Geothermal power plants
Energy analysis
Working fluid selection
Publisher: Inderscience
Abstract: An existing organic rankine cycle power plant which uses isobutane as working fluid is re-evaluated for different working fluids. The plant is first modelled by EES software; then the model is simulated for different working fluids obtaining heat transferred through the heat exchanger, net work output, energy and exergy efficiencies, and mass flowrate of the working fluid. Two parametric studies are conducted to evaluate the thermodynamic performance of the plant under a range of turbine inlet temperature (130°C–155°C) and geothermal resource temperature (152°C–161°C) for each working fluid. The study reveals that the highest cycle energy and exergy efficiencies are observed for R-152a at any geothermal resource temperature. R-152a resulted with 13.1% and 58.2% cycle energy and exergy efficiency, respectively at operation condition, whilst the lowest efficiency and net work output is calculated under n-butane presence.
URI: https://doi.org/10.1504/IJEX.2023.10053807
https://hdl.handle.net/11147/13227
ISSN: 1742-8297
Appears in Collections:Energy Systems Engineering / Enerji Sistemleri Mühendisliği
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Show full item record



CORE Recommender

Page view(s)

170
checked on Nov 18, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.