Please use this identifier to cite or link to this item: https://hdl.handle.net/11147/12650
Title: Development of Single-Use Thin Film Electrodes Based on Zn2sno4 on In2o3:sno2 Substrates With Their Biosensing Applications
Authors: Yurttaş, Betül
Maral, Meltem
Erdem, Arzu
Özyüzer, Lütfi
Keywords: Dopamine detection
Electrochemical biosensor
Magnetron sputtering
Thin film electrode
Publisher: Elsevier
Abstract: Dopamine (DA) has a significant impact on the emergence and treatment of certain diseases (e.g., Alzheimer's and Parkinson's diseases). Therefore, monitoring of DA is important, and using biosensors is a favorable option instead of time-consuming and expensive conventional methods. In biosensor manufacturing, thin films have become a rapidly emerging field. In this study, a non-enzymatic electrochemical biosensor based on thin film electrodes is developed for monitoring DA levels. The thin film electrodes (ZTO/ITO) are developed by deposition of Zn2SnO4 (ZTO) on In2O3:SnO2 (ITO) substrates by magnetron sputtering. 3-aminopropyltriethoxysilane (APTES) is used to modify the surface of these electrodes. Physical, optical, and structural properties of the electrodes are determined by applying surface profilometry, UV–VIS–NIR spectrophotometry, X-ray diffraction (XRD), and scanning electron microscopy (SEM) measurements. According to these measurements, it has been observed that the ZTO/ITO combination has a higher optical transmission value than the bare ITO, depending on the deposition time and the oxygen concentration used during ZTO deposition. In addition, the ITO thin film has a crystalline structure, while the ZTO thin film has an amorphous structure and both thin films have a good surface morphology. As electrochemical analysis, cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and differential pulse voltammetry (DPV) measurements are performed. As a result of CV and EIS measurements, a remarkable change (63.54%) was observed after applying APTES modification onto the surface of ZTO/ITO electrode, and the ones obtained by DPV showed successful detection of DA by APTES modified ZTO/ITO. In addition, the experiments in the presence of interferences such as ascorbic acid (AA), uric acid (UA), bovine serum albumin (BSA), and fish sperm double-stranded DNA (fsDNA) show that the electrodes can be successfully applied for voltammetric determination of DA. The detection limit of DA was estimated to be 0.013 µM in the range of DA between 0.1 and 1 µM, and sensitivity was calculated and found to be 11.057 μA μg−1 mL cm−2, which means ZTO/ITO electrodes have a good sensitivity.
URI: https://doi.org/10.1016/j.mtcomm.2022.104906
https://hdl.handle.net/11147/12650
ISSN: 2352-4928
Appears in Collections:Physics / Fizik
Scopus İndeksli Yayınlar Koleksiyonu / Scopus Indexed Publications Collection
WoS İndeksli Yayınlar Koleksiyonu / WoS Indexed Publications Collection

Files in This Item:
File Description SizeFormat 
1-s2.0-S2352492822017470-main.pdf
  Until 2025-01-01
Article (Makale)5.79 MBAdobe PDFView/Open    Request a copy
Show full item record



CORE Recommender

SCOPUSTM   
Citations

1
checked on Dec 21, 2024

WEB OF SCIENCETM
Citations

1
checked on Dec 7, 2024

Page view(s)

272
checked on Dec 23, 2024

Google ScholarTM

Check




Altmetric


Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.